DS-MDS003 Dock Station User Manual
UM DS-MDS003 042721NA 15
6. Optional: To upload files at a specific time, enable upload schedule and set Upload Time.
NOTE: If upload schedule is disabled, the files will be uploaded to platform in real time.
7. Select OK.
Result
If platform connection succeeded, will appear on the upper right corner of the software page.
NOTE: If connection failed, check the platform parameters and network communication.
3.5. Manage Storage
3.5.1. Set Local Storage
You can edit and manage local storage.
Steps
1. Go to Configuration → Basic.
2. View local storage information, including Total Space, Used Space, Free Space, and Usage.
3. Set Total Free Space and Clear Space.
CAUTION: The earliest data will be cleared according to time. Back up data in time to avoid data
loss.
Example: If you set Total Free Space as 10 GB, and set Clear Space as 5 GB, when the storage disk free
space is less than or equal to 10 GB, 5 GB storage space will be cleared automatically.
4. Optional: After uploading the body camera data to the software, the data will be cleared automatically.
If you do not want to clear the data automatically, disable Clear Body Camera Data.
5. Select OK to save the settings.
3.5.2. Connect to Storage Server
The storage server can store body camera files as expansion storage.
Before You Start
• Allocate the storage server.
• The software communicates normally with the storage server.
Steps
1. Go to the Configuration → Storage.
2. Select Storage Type according to server type.
3. Enter server parameters, including IP Address, Port No., etc.