EasyManuals Logo

HIKVISION HWT-B123-M User Manual

HIKVISION HWT-B123-M
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
Digital Video Recorder User Manual
120
Figure 8-9 Set PTZ Linking of Alarm Input
Step 15 If you want to set handling action of another alarm input, repeat the above steps or just
copy the above settings to it.
Figure 8-10 Copy Settings of Alarm Input
Step 16 (Optional) Enable the one-key disarming for local alarm input 1 (Local<-1).
1) Check the checkbox of Enable One-Key Disarming.
2) Click the Settings button to enter the linkage action settings interface.
3) Select the alarm linkage action (s) you want to disarm for the local alarm input 1. The
selected linkage actions include the Full Screen Monitoring, Audible Warning, Notify
Surveillance Center, Send Email and Trigger Alarm Output.