Do you have a question about the Hilti HIT-RE 500 V3 and is the answer not in the manual?
Seismic loading | Yes |
---|---|
Strength class | High strength |
Packaging | Foil pack |
Chemical base | Epoxy resin |
Temperature range | -5°C to +40°C |
Cure time | 24 hours at 68°F (20°C) |
Base material | Concrete |
Approvals / Test Reports | ETA, ICC-ES |
Cleaning procedures | Please refer to the HIT-RE 500 V3 Instruction for Use |
Storage and transportation temperature - min | 41 °F |
Storage and transportation temperature - max | 77 °F |
Tensile strength | Please refer to the HIT-RE 500 V3 Instruction for Use |
Application | Anchoring |
Safe working temperature range | 41°F to 104°F (5°C to 40°C) |
Details hazard symbols, chemical components, and associated risks like skin burns and allergic reactions.
Details working time and curing times (initial and full) at various temperatures, presented in both Fahrenheit and Celsius.
Step-by-step visual guide for installing rebar anchors, including drilling, cleaning, and injection.
Visual instructions for installing HIS-N anchors, covering drilling, cleaning, and adhesive dispensing.
Warns about mortar splashes, eye damage, and mandates wearing safety glasses and gloves during handling.
Emphasizes dry boreholes and proper cleaning to prevent load value failures, detailing the use of Hilti accessories.
Highlights that failure to follow setting instructions can lead to fastening point failure.