Due to the measuring principle employed, the results of measure-
ments can be negatively affected by certain ambient conditions.
These include, for example, the proximity of devices that produce
strong magnetic or electro-magnetic fields, vibrations and temperature
changes.
Rapidly changing measuring conditions can falsify the results.
When the product is brought into a warm environment from very cold
conditions, or vice-versa, allow it to become acclimatized before
use. Big differences in temperature can lead to incorrect operation and
incorrect results.
When adapters or accessories are used, make sure they are
mounted securely.
The measuring tool is designed for the tough conditions of jobsite
use, but as with other optical and electrical products (e.g. binoculars,
spectacles, cameras) it must be handled with care.
The specified operating and storage temperatures must be ob-
served.
2.2 Additional safety instructions
Personal safety
Keep the measuring tool well away from all implants.
Comply with the national accident prevention regulations.
Do not use the measuring tool to examine humans or animals.
Operation of the device in the proximity of expectant mothers or persons
with a cardiac pacemaker is not permissible.
Electrical safety
Remove the battery prior to storage.
Using and handling the measuring tool
Prior to use, always check the measuring tool's presettings and the
settings you have made yourself.
After switching on and while using the product, always pay attention to
the information and warnings that appear on the display.
Keep the underside of the scanner and the wheels clean as these parts
can have an influence on measuring accuracy.
Do not affix stickers or adhesive labels to the sensor area at the back
of the measuring tool. Metal plates / labels, in particular, will affect
measuring results.
While measuring is in progress, always keep all 4 wheels in contact with
the surface being scanned. Do not pass over steps or edges.
While scanning is in progress, to avoid influencing the scan hold the
measuring tool only by the grip provided for the purpose.