2 Installation
2.1 General instructions
! Do not install the device at places exposed to the bad weather or to the extreme
temperatures.
! The central unit is protected from the opening, but the installation in a safe place is a
greater protection of the device.
! For a strong and safe fixing, it needs making sure the wall surface is plane.
! Fixing the device by the four fishers included in the central unit and no replacing them with
others of more small size.
! Fixing the central unit at a height that allows an easy access to the frontal panel.
! The central unit must be connected with an alarm system according to CEI 79-3 Standard
or similar.
2.2 Power supply
It ‘s important to know that the entire system is powered exclusively by the 12V 7,5Ah lead
battery inside of the burglary central unit; the lead battery is constantly in charge by the power
supplier/battery connected to the 230V~ main power supply.
28
1.3 Technical features
! Operating voltage: 230V~ ±10% 50Hz
! Maximun current absorption: 140mA
! Service output voltage: 13V! ±5%
! Maximum current supplied in services output: 650mA
! Fuse on services output voltage: F type 1A
! Maximum current supplied in sirens output: 3A (connected to the battery)
! Fuse on sirens output: F type 3,15A
! Maximum current supplied by power supplier : 1A
! Minimum operating temperature: 5±2°C
! Maximum operating temperature: 40±2°C (relative humidity 93±2%)
! Container protection level: IP30
! Buffer battery: 12V 7Ah
! Transformer primary fuse: F type 250mA
! Transformer secondary fuse: F type 2A
! Central unit dimensions: 280x230x95mm
! Electronic key dimensions: 50x20x10mm
! Insulation class:
! Prestation level: 1st
!
29
InstallationPROTEC5X - User’s manual
230V~
50Hz
main power supply
Switch
WARNING!
The main power supply 230V~ has to be connected to the power supplier/battery
charger by two 1,5mm² double-isolation wires coming from a sectioning switch(i.e. a
magneto-thermic protection switch) used exclusively for the burglary central unit.
Inside of the central unit positioning orderly the two wires, locking them by wrappers.