EasyManua.ls Logo

Hirschmann BAT54-F - Configuring the CRON Job

Hirschmann BAT54-F
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
More services
BAT54-Rail/F..
Release
7.54
06/08
12.7
Scheduled Events
493
12.7.3 Configuring the CRON job
The following parameters are available in the BAT for configuring CRON
jobs:
D Entry active
Activates or deactivates the entry.
D Default: Active
D Time base
The 'Time base' field determines whether time control is based on real
time or on the device's operating time.
D Real time: These rules evaluate all time/date information.
D Operation time: These rules only evaluate the minutes and hours since
the last time the device was started.
D Default: Real time
Configuration tool Call
LANconfig Date & time
General CRON table
WEBconfig, Telnet Expert configuration > Setup > Config > CRON table

Table of Contents

Related product manuals