Service Manual DS 85
© Hirschmann Rev.G 10/05/15 190166_G.DOCXG
46
Using a calibrated inclinometer placed flat on the main boom, verify that the indicated boom angle
matches the measured boom angle within +/- 0.2 degrees.
Check the sensor outputs screen for 0°, 45°, 60°, and 70°
main boom angle
millivolts
45°
60°
70°
0502mV 2025mV
30.6 f t 55.7°