14.5 Floor Dry Running
Operation steps of floor dry running (see the section
5.1.2.2):
(1) In standby state, press reset key ⑤and hot water
key② for three seconds, to start dry test run of floor.
The temperature of test run depends on running
time. Setting temperature is shown during running
and the residual running time will be shown too.
(2) Effluent temperature is set as 25ºC for running 72
hours, 35ºC for 48 hours and 40ºC for running 48
hours respectively.
(3) After test run of supplying hot water for seven days,
effluent temperature comes back to setting value. If
the temperature is not set, it will be default value
(35ºC).
(4) When floor is in dry run, the unit can be started and
closed, but the functions and effluent temperature
can not be changed.
(5) The time of floor dry run is cumulative. After the unit
is closed, it will enter floor dry run when it starts next
time.
Ɣ )ORRUKHDWLQJV\VWHPPXVWEHFRPPLVVLRQHGEHIRUH
use.
Ɣ 7KHFRPPLVVLRQLQJRIIORRUKHDWLQJV\VWHPPXVWEH
made by the construction unit.
Ɣ 7KHIORRUGU\UXQRIIORRUKHDWLQJV\VWHPPXVWGR
after the top coat is dried thoroughly(21days after
filling layer is finished at least). At first time of
supplying heat, increase hot water temperature
steadily till designed value. Adjust heating pipeline
connected to water knockout trap and water
collector until it works normally.
Ɣ ,QKHDWLQJHIIHFWRIIORRUKHDWLQJV\VWHPWKH
temperature shown in black ball thermometer
1.5m from the center of room is taken as reference
for evaluation and appraisal.
Day
15. Maintenance and Repair
Regularly check water module as required in
section 11.1 “test run”.
Power cut outdoor unit and water module before
maintenance and repair.
Check the followings once at least every year:
(1) Water pressure
Check water pressure is above 0.1Mpa before
startup. Supplement water if lower than 0.1MPa.
(2) Filter
Clean water filter and filter net.
(3) Safety valve
① Stir manual switch of safety valve to check
er water flows out;
② If no water comes out, contact local dealer.
③ If water continuously flows out, firstly close
valve on water pipeline and contact local
dealer
.
(4) Drainage hose in safety valve
Check safety valve hose drains water smoothly.
(5) Electrical box
Check electrical box is loosened or not.
(6) Water module heater
Check heater is wrapped tightly by thermal
material in water module heater.
(7) Water circuit deposit and blockage
Ɣ $IWHUUXQQLQJIRUDZKLOHIRUHLJQSDUWLFOHVGXVW
and calcium carbonate contained in water and
other mineral materials may deposit on surface
of plate heat exchanger. Consume excessive
electricity .
Ɣ 5HJXODUO\FOHDQZDWHUILOWHUUHJDUGLQJEORFNDJH
degree in water filter. Otherwise filter net may be
damaged due to excessive pressure, and filter
failure is caused.