EasyManua.ls Logo

Hitachi DKC-F910I-1R9RVM - Page 25

Hitachi DKC-F910I-1R9RVM
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 12 Input power specifications
Item Component Specification
Rated power Controller 1,960 V
Input power
1
Controller Single-phase AC
50 Hz/60 Hz
200 V to 240 V
Input current
1,2
Controller 9.8 A
Steady current
3
Controller 4.9 A
Leakage current Controller 1.75 mA
Inrush current Controller 1st (0-p): 30 A
2nd (0-p): 20 A
1st (0-p) time: 25 ms
Power cord plug type Controller IEC60320 C14
Notes:
1. When planning the air-conditioning equipment and power-supply system, use the
multiplied value of [Input Power] × [Input Current].
2. The maximum current of AC input is not a redundant configuration.
3. The maximum current of AC input is a redundant configuration.
Table 13 Input voltage and input frequency requirements
Frequency Input Voltage (AC) Conditions Tolerance (%)
60 Hz ±2 Hz 200 V to 240 V 1 phase
2 wire + ground
+10% or -11%
50 Hz ±3 Hz 200 V to 240 V 1 phase
2 wire + ground
+10% or -11%
60 Hz ±2 Hz 100 V to 120 V 1 phase
2 wire + ground
+10% or -11%
50 Hz ±3 Hz 100 V to 120 V 1 phase
2 wire + ground
+10% or -11%
Electrical specifications
Chapter 3: Specifications
Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide 25

Related product manuals