31
Table 1
Indications of the pilot lamp
The pilot
lamp lights
or blinks in
red.
Before
charging
Blinks
Lights for 0.5 seconds. Does not
light for 0.5 seconds. (o for
0.5 seconds)
While
charging
Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not
light for 0.5 seconds. (o for
0.5 seconds)
Charging
impossible
Flickers
Lights for 0.1 second. Does not
light for 0.1 seconds. (o for
0.1 seconds)
Malfunction in the battery
or the charger.
The pilot
lamp lights
in green.
Overheat
standby
Lights
Lights continuously
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
(2) Regarding the temperatures of the battery
The temperatures for batteries are as shown in the Table 2, and batteries that have
become hot should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
Batteries Temperatures at which the battery can be recharged
BSL1430, BSL1830 0°C – 50°C
(3) Regarding recharging time
Depending on the combination of the charger and batteries, the charging time will become
as shown in Table 3.
Table 3 Charging time (At 20°C)
Charger
Battery
UC18YRSL
BSL1430, BSL1830 Approx. 45 min.
NOTE
The recharging time may vary according to the ambient temperature and power source
voltage.
4. Disconnect the charger’s power cord from the receptacle.
5. Hold the charger rmly and pull out the battery.
NOTE
After operation, pull out batteries from the charger rst, and then keep the batteries
properly.
000Book_DV14DBL_ChS.indb 31000Book_DV14DBL_ChS.indb 31 2015/4/28 16:10:182015/4/28 16:10:18