EasyManua.ls Logo

Hitachi HISCREW 2000 Series - Page 18

Hitachi HISCREW 2000 Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
q Press the START button.
Make sure that the air compressor starts.
For the air dryer prestarting (
p.
14) disabled:
Make sure that the built-in air dryer starts
simultaneously.
For the air dryer prestarting enabled:
Make sure that the built-in air dryer prestarts,
the AUTO START light flashes for 3 minutes,
and then the air compressor starts.
w Make sure that the oil level during operation
is kept within the range between the red lines.
e If it is below the lower line, follow the proce-
dure on page 18 and replenish the genuine
synthetic oil (NEW A OIL 2000).
r Digital monitor displays run hour in 10 hours
as a unit.
Press the SELECT button on the instrument
panel and check if the discharge temperature
is within the range between 65°C and 100°C.
(After temperature stabled)
t Make sure that, 5 to 10 minutes after starting,
the refrigerant pressure gauge reads 0.41 to
0.73 MPa.
y Make sure that, about 20 minutes after start-
ing, the automatic condensate trap starts drain-
ing the condensate.
3. HOW TO OPERATE [Daily Operation]
3.5.3 Operation
3.5.4 Stop
q Press the STOP button.
The compressor stops.
w Be sure that the pressure at DISCHARGE AIR
PRESSURE GAUGE indicates 0 (It returns to
0 for about 1 or 2 minutes after stop.)
e Fully close the valve on discharge side.
r Disconnect the power.
④ ①
⑥
⑤
②
②①
④
③
Power
Supply