12
3.4.1 Setting of Capacity Control Mode
As listed in the table below:
The S- and M-type As provide two ca-
pacity control modes each.
You can select either one of them by setting the
No. 3 & 4 pins of the DIP switch SW2 located
on the printed circuit board.
3. HOW TO OPERATE [Setting of the Control Functions]
3.4 Setting of the Control Functions
When you use an external air dryer under the A mode
of capacity control (U-type + I-type + P-type), enable it
to keep operating even when the A automati-
cally stops. Thus protect the external air dryer from stop-
ping and restating frequently.
For more information on the capacity control sys-
tem, see pages 29 through 30.
IMPORTANT
Do not select the U-type when your A specifies
the discharge of 0.92 MPa.
IMPORTANT
NOTES:
1. The shaded cells indicate a standard factory setting.
2. The + mark indicates that the CPU automatically selects
either of the 2 or 3 capacity control types whichever is
appropriate.
3. Do not set the SW2 No. 3 & 4 to other than the above.
3.4.2 How to Set Capacity Control Type
to U
q Disconnect the power.
w Remove the starter/control box cover.
e Place the No. 4 pin of the DIP switch SW2 in
an off position.
r Return the starter/control box cover to its origi-
nal place.
t Reconnect the power.
y Display the capacity control setting screen on
the digital monitor (
p. 9). Make sure that
the U as 0.U
**
is displayed.
U Mode L Mode A Mode L Mode
(U Type) (U+I Type)
(U+I+P Type)
(U+I Type)
No.3 ON ON ON ON
No.4 OFF ON OFF ON
0.U 0.L 0.A 0.L
A Type S-type M-type
Settings of
DIP Switch
SW2
Capacity Control
System
Display on Digital Monitor
②
④
⑥
①⑤
Power
Supply
16
CN16
51
CN17
41
CN8
21
CN2
19
CN1
17
CN15
17
Y3 Y1Y1
CPU
Y52C
Y2D
Y52
CN13
13
CN3
15
CN5
17
CN4
17
CN6
15
CN14
41
Y42
Y6
C38
C4D
C39
ICO
GND
CN11 CN12
14
CN18
13
CN19
13
CN22
14
CN21
15 12
CN10
1
18
2
CN9
SW1
14
SW2
CN7
HC30CPU−
SW2
14
ON
OFF
DIPSwitch
PrintedCircuitBoard
DRYER
ドライヤ
エコモド
SELECT
警報
SHUTDOWNALARM
RESET
表示切替
10h×
リセット
故障
C温度
TEMP
RUNNINGCONTROL
運転管理
ECOMODE
故障ド
ERRORCODE