EasyManua.ls Logo

Hitachi HUS VM - User Manual

Hitachi HUS VM
530 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Command Control Interface
User and Reference Guide
Hitachi Virtual Storage Platform G1000 and G1500
Hitachi Virtual Storage Platform F1500
Hitachi Virtual Storage Platform G200, G400, G600, G800
Hitachi Virtual Storage Platform F400, F600, F800
Hitachi Virtual Storage
Hitachi PlatformUnified Storage VM
Hitachi Universal Storage Platform V/VM
MK-90RD7010-32
May 2017

Table of Contents

Other manuals for Hitachi HUS VM

Questions and Answers

  • C
    Christina WaltersAug 2, 2025
    What to do if the ALARM LED is on due to a temperature problem in Hitachi HUS VM?
    • G
      gpierceAug 2, 2025
      If the ALARM LED is on and you suspect a temperature issue, power down the Hitachi storage system. Reduce the room temperature to the specified operating range, and then power the system back on. If the problem persists, contact the support center for assistance with power cycling.
  • D
    Daniel WilliamsAug 10, 2025
    What to do if there is a general power failure in Hitachi HUS VM?
    • J
      jfryeAug 10, 2025
      In the event of a general power failure with your Hitachi Storage, turn off all PDU switches and breakers. Once the facility power is stable, turn them back on and power up the system. If you need further assistance, contact Hitachi Data Systems support.
  • K
    kelly37Aug 17, 2025
    What to do if a fence message is displayed on the console of Hitachi HUS VM Storage?
    • J
      jonathanharrisAug 18, 2025
      If you see a fence message displayed on the console of your Hitachi Storage, first determine if there is a failed storage path. If a failed path exists, toggle the RESTART switch and retry the operation. If the fence message reappears, contact the support center for further assistance.
  • C
    Christopher PenningtonAug 26, 2025
    How to troubleshoot an error message displayed on Hitachi HUS VM Storage?
    • A
      Amy WaltersAug 26, 2025
      To address an error message displayed on your Hitachi Storage, first identify the type of error using the SIM codes section. If possible, resolve the underlying cause of the error. If you are unable to correct the error, contact the support center for assistance.

Summary

3 CCI functions

System configuration using CCI

Describes system configurations using both in-band and out-of-band methods for connecting to CCI servers.

User authentication

Details how CCI enables user authentication using operation authority and the mandatory nature of this function for certain operations.

4 Starting up CCI

Starting up on UNIX systems

Provides instructions for starting CCI instances on UNIX systems, covering both single and multiple instances.

Starting up on Windows systems

Details the steps for starting CCI instances on Windows systems, including single and multiple instances.

5 Provisioning operations with CCI

Virtual volume (Dynamic Provisioning) operations

Explains how to create LDEVs of virtual volumes for Dynamic Provisioning and make them available to hosts.

Server Priority Manager operations

Details how Server Priority Manager prioritizes host I/O operations for high-speed processing on specified hosts.

6 Data replication operations with CCI

Using CCI with ShadowImage and TrueCopy

Describes how CCI allows performing ShadowImage and TrueCopy operations by issuing commands from the host to the RAID storage system.

7 Data protection operations with CCI

9 Troubleshooting

General troubleshooting

Provides general advice for troubleshooting CCI software issues, including checking server hardware/software and restarting servers.

Error messages and error codes

Details system log messages and command error messages, providing recommended actions for resolving error conditions.

Hitachi HUS VM Specifications

General IconGeneral
BrandHitachi
ModelHUS VM
CategoryStorage
LanguageEnglish

Related product manuals