5 REMOTE CONTROLLER OPERATION
5.1. LIQUID CRYSTAL REMOTE CONTROL PC-ART
Fan speed indicator
Indicator of Total ventilator
Operation Mode Indicator
Run indicator (Red lamp)
RUN/STOP switch
MODE (Operation Mode Selection) switch
FAN SPEED (Fan Speed Selection) switch
Up & down panel operation switch
VENTI (ventilator operation) switch
SELECT (Day/Schedule) switches
ON/OFF TIMER switch
OK switch
RESET (Filter Reset Switch)
TEMP (temperature setting) switches
T.RUN (test run indication)
ABNML (alarm) indicator
SET TEMP (set temperature) indicator
1234S indicator (setting schedule number)
Mon Tue ... Sun indicator (day of the week indicator).
Swing louver indicator
SERVICE mode indicator
Time indicator.
Time indicator
NOTE:
If the LOW fan speed is selected and the outdoor temperature is
higher than 21°C, the compressor is subjected to an excessive
load when operating in heating mode.
Therefore, the fan speed should be set to HIGH or MEDIUM to
avoid activating the safety devices.
When the system is restarted after a shutdown of more than
approximately 3 months, the system should be checked by your
service provider.
Turn off the main switch when the system is to be inoperative for
a long period of time. Otherwise the system consumes electricity
as the oil heater remains active even though the compressor is
stopped.