4  Connect them with the wiring connectors to CN17 in the 
electrical box as the following gure.
CN37
IC1
CN9
DSW9
21
ON
8
7
123456
3
4
5
RSW1
6
2
DSW6
8
7
3
2
1
4
5
0
9
6
21
9
RSW2
0
1
DSW5
CN11
CN17
HA
CN10
CN6
CN33
CN3
CN4CN14
THM5
CN5
LED6
CN28
CN2
THM4
LED1
Motor wiring for auto 
louver (on air panel)
Cable band
Connector 
(CN17)
5  After completing the wiring connection of the air panel, 
attach the air inlet grille. Perform the attaching work in the 
reverse procedure of removing.
6  Fasten the other end of the support string to the 
corresponding hole at part Ⓐ in the panel as shown. The 
fact that the air inlet grille is square allows it to be rotated to 
be xed from any direction.
Supporting string
Hole to secure the 
support string to the 
air panel
Part Ⓐ
7  TEST RUN
! DANGER
•  Do not put any foreign materials within the air inlet grille 
operation range. It may lead to injury or damage.
•  Keep the wire from re or sharp edge. Breaking wire may cause 
of injury due to air inlet grille or air lter falling.
•  If the air inlet grille or the air lter falls, it may cause injury.
1  After completing installation of the air panel, Test Run should 
be performed according to installation and maintenance 
manual for the indoor unit.
2  Perform the checking work for the louver during the test run. 
Do not move the louver by hand. If moved, the auto-swing 
mechanism will be damaged.
a.  Press “
” (run / stop), and the operation is started. 
Select the air ow direction by “ ” or “ ”.
b.  The louver angle is changed by pressing “ ” or “ ”.
LCD Indication
The auto swing operation will be started to select “ ” 
(auto swing). At this time, LCD indication displays the swing 
repeatedly.
3  If there is a louver that does not move, check the connection 
of the louver wiring connector (CN17).
? NOTE
•  Adequate  and  optimal  airow  is  dependent  on  application  and 
installation practices which  include  positioning of  ofce equipment, 
room structure, and ofce cubicle or furniture layout. Adjust airow 
for maximum comfort.
•  The position of the louvers may not coincide with the louver position 
indicator on the LCD during auto swing operation. When adjusting 
the louver angle, set it according to the louver position on the LCD.
•  Even if the “
” or “ ” are pressed to stop the auto swing function, the 
louver is not stopped immediately.
•  If the cooling operation is performed with greater than 80% relative 
humidity, condensation may form on the air panel or louver surfaces.
TEST RUN
PMML0569 rev.2 - 07/20239
EN