Fig. 9 -4 Power module circuit (U is OFF, V is ON)
+–
Since current flows at point B only when U
+
transistor and V
transistor are ON, the current waveform
at point B becomes intermittent waveform as shown in Fig. 3. Since current at point B is approximately
proportional to the input current of the air conditioner, input current is controlled by using DC current
(Id) detection resistor.
<Reference>
If power module is defected, self diagnosis lamps on the MAIN P.W.B. may indicate as shown below:
Table 9 -1
Fig. 9 -5
9 -
R008
C031
74