– 173 –
LD303
LD302
LD301
MODULE D'ALIMENTATION DU SYSTÈME
POSITION DE MESURE DE TENSION CC ()
POSITION DE MESURE DE TENSION CC ()
HIC C.I.
INTERRUPTEUR DE
SERVICE
VIS (DANGER DE DÉCHARGE ÉLECTRIQUE)
L
D
3
0
2
L
D
3
0
1
RED RED
UNITÉ EXTÉRIEURE EXPOSÉE EN PLEIN SOLEIL OU
FLUX D'AIR BLOQUÉ
MOTEUR DE VENTILATEUR ③CIRCUIT OH MOTEUR DE
VENTILATEUR TENSION TRÈS BASSE
THEMISTOR ②BRANCHEMENT DU
THEMISTOR DÉFECTUEUX
CIRCUIT THERMISTANCE
FUITE DE FLUIDE FRIGORIGÈNE
COMPRESSEUR
MODULE D'ALIMENTATION DU SYSTÈME
2sec.
CÂBLE MAL BRANCHÉ.
CÂBLE OUVERT. 
CIRCUIT D'INTERFACE ENTRE L'UNITÉ
INTÉRIEURE ET L'UNITÉ EXTÉRIEURE
MOTEUR DE VENTILATEUR
CIRCUIT MOTEUR VENTILATEUR
FUITE DE FLUIDE FRIGORIGÈNE
COMPRESSOR ③CIRCUIT OH THEMISTOR
MOTEUR DE VENTILATEUR 
CIRCUIT OH MOTEUR DE VENTILATEUR
DANGER
CONTRÔLERQUELE
VOLTAGEESTDE
MOINSDE10V.C.C.
AUPOINTDEMESURE.
NEPA STOUCHERLA
VISDUMODULEDE
PUISSANCEDUSYSTÈME
ÀCAUSEDESON
VOLTAGEÉLEVÉ.
NETOUCHERAUCUNE
PARTIESURLE
BOÎTIERCONTENANT
L'INTERRUPTEURDE
BRANCHEMENT.
ATTENDREDIXMINUTES
APRÈSAVOIRÉTEINT
L'INTERRUPTEURDE
COURANTQUAND
L'OPÉRATION
D'ENTRETIENEST
TERMINEÉ.
(
C.C.DE400V
)
MODULE D'ALIMENTATION DU SYSTÈME
COMPRESSEUR ③P. W . B .
MODULE D'ALIMENTATION DU SYSTÈME
COMPRESSEUR ③P. W . B .
MODULE D'ALIMENTATION DU SYSTÈME
COMPRESSEUR ③P.W.B.
P. W . B .
P. W . B .
SOURCE D’ALIMENTATION ANORMALE
CÂBLE MAL BRANCHÉ
MODULE D'ALIMENTATION DU SYSTÈME
P.W.B.
(3)
(2)
(1)
POINTDEMESURE
CN12
CN6
CN18
CN14
CN13
CN11
CN5 CN10 CN9
CN8
CN15
CN2
CN7
YEL
BLU
RED
BRN
GRN1
WHT
BLK
GRN2
RED
WHT
N
DANGER
(
DC400V
)
CUTTHEPOWER
SOURCEANDWAIT
MORETHAN10
MINUTESBEFORE
SERVICEWORK.
DONOTTOUCHTHE
SCREWSATSYSTEM
POWERMODULEDUE
TOHIGHVOLTAGE.
DONOTTOUCHTHE
OTHERCOMPONENTS
WHENOPERATINGTHE
SERVICESWITCH.
CONFIRMTHEDC
VOLTAGEATTHE
MEASURINGPOINT
SHOWNINFIGURE
MUSTBELESS
THAN10V.
MODE D'ECLAIRAGE DU VOYANT D'AUTO-DIAGNOSTIC
MODÈLE RAC-50WX8, RAC-D18EX3
MODE D’ALLUMAGE AUTO-DIAGNOSTIC
NOM AUTO
-
DIAGNOSTIC
PENDANT LE FONCTIONNEMENT
LD303 (ROUGE) S’ALLUME
DÉTAILS
POINT DE CONTRÔLE
PRINCIPAL
: ALLUMÉ : CLIGNOTE : ÉTEINT
FONCTIONNEMENT
NORMAL
FONCTIONNEMENT
COMPRESSEUR
PAS UN DYSFONCTIONNEMENT
SURCHARGE
VITESSE DE
ROTATION
VALEUR
RÉGLÉE
LA VITESSE DE ROTATION EST
CONTRÔLÉE AUTOMATIQUEMENT
POUR PROTÉGER LE
COMPRESSEUR EN CAS DE
SURCHARGE
INDIQUE UN ÉTAT DE PROTECTION
DE SURCHARGE
PAS UN DYSFONCTIONNEMENT
DURÉE
SURCHARGE
SURCHARGE
ARRÊT
RÉINIT.
COUPURE
COURANT
DE CRÊTE
ROTATION
BASSE VITESSE
ANORMALE
ÉCHEC DE
COMMUTATION
RÉINIT. DU MICROPROCESSEUR
(NORMAL QUAND LE COMMUT.
M/A A ÉTÉ MIS SUR MARCHE)
LE COURANT DE CRÊTE DU
COMPRESSEUR A DÉPASSÉ
LA LIMITE MAXIMUM
POSITION DU ROTOR DE
COMPRESSEUR PERDUE
VALEUR ANORMALE
THEMISTOR (OUVERT OU
COURT-CIRCUIT) DÉTECTÉE.
ÉCHEC DE COMMUTATION DE
DÉMARRAGE SYNC. BASSE
FRÉQUENCE SUR POSITION
DE DÉTECTIONÉ
PAS UN DYSFONCTIONNEMENT
EXEMPLE DE
CLIGNOTEMENT (5 FOIS)
1 FOIS
2 FOIS
3 FOIS
4 FOIS
5 FOIS
6 FOIS
7 FOIS
8 FOIS
9 FOIS
13 FOIS
14 FOIS
12 FOIS
10 FOIS
PROCÉDURE DE RÉFRIGÉRATION, POMPE
ARRÊTÉE OU OPÉRATION INDÉPENDANTE DE
L’UNITÉ EXTÉRIEURE
1. METTEZ L’APPAREIL HORS TENSION ET
REMETTEZ-LE SOUS TENSION.
2. ATTENDEZ AU MOINS 1 MINUTE.
3. APPUYEZ SUR LE COMMUTATEUR DE
MAINTENANCE (SUR LE C.I.) PENDANT
PLUS DE 1 SECONDE.
L’OPÉRATION DE MAINTENANCE DÉMARRE.
POUR ARRÊTER CETTE OPÉRATION, APPUYEZ
À NOUVEAU SUR LE COMMUTATEUR DE
MAINTENANCE (PENDANT PLUS DE 1
SECONDE).
POUR RELANCER LE FONCTIONNEMENT
NORMAL, COUPEZ ET RALLUMEZ À NOUVEAU
LA SOURCE D’ALIMENTATION.
AFIN DE PROTÉGER LE COMPRESSEUR
D’ÉVENTUELS DOMMAGES, NE PAS FAIRE
FONCTIONNER L’APPAREIL PENDANT PLUS DE
5 MINUTES AVEC LA VANNE DE MAINTENANCE
FERMÉE.
OPÉRATION DE MAINTENANCE
PENDANT L’ARRÊT LD303 (ROUGE) S’ÉTEINT
ARRÊT NORMAL
ARRÊTÉ PAR LE THERMOSTAT
OU LE CONTRÔLEUR
COUPURE LIMITE
INFÉRIEURE
SURCHARGE
FONCTION DE PROTECTION
ANTI-SURCHARGE DEMANDE
UNE VITESSE INFÉRIEURE À LA
VITESSE MINIMUM DU COMPRESSEUR
AUGM. TEMP.
OH THEMISTOR
THEMISTOR
ANORMAL
SURCHAUFFE COMPRESSEUR
DÉTECTÉE PAR OH
THERMISTANCE.
ÉCHEC
D’ACCÉLÉRATION
ERREUR DE
COMMUNICATION
SOURCE
D’ALIMENTATION
ANORMALE
ERREUR DE
BLOCAGE DE
VENTILATEUR
EEPROM:ERREUR
DE LECTURE
PAS D’ACCÉLÉRATION
SUPÉRIEURE À LA VITESSE
MINIMUM POUR LE
COMPRESSEUR.
COMMUNICATION ENTRE
UNITÉINTÉRIEURE ET UNITÉ
EXTÉRIEURE INTERROMPUE
SOURCE D’ALIMENTATION
ANORMALE DÉTECTÉE
RÉGIME VENTILATEUR
EXTÉRIEUR N’ATTEINT PAS LA
VALEUR PRÉVUE
LE MICRO-ORDINATEUR NE
PEUT LIRE LES DONNÉES DE
LA MÉMOIRE MORTE (EEPROM)
S’ALLUME PENDANT
0,25 SEC À DES
INTERVALLES DE 0,25 SEC.
CONVERTISSEUR
ACTIF DÉFECTUEUX
SURTENSION DÉTECTÉE PAR
LE MODULE D'ALIMENTATION
DU SYSTÈME