– 174 –
CHECKING THE REFRIGERATING CYCLE
2.9630.14
2.6226.72
2.3123.58
2.0320.73
1.7818.14
1.5515.79
1.3413.66
1.1511.74
0.9810.02
0.83 8.48
0.70 7.10
0.58 5.89
0.47 4.81}
Outdoor air
temperature
(℃)
50
45
40
35
30
25
20
15
10
5
0
-5
-10
(R410A)
Lo Hi
Connect U,V,W phase leads to the
power module again and operate the
air conditioner.
Is the self-diagnosis lamp mode as
shown on the right?
Stop to operate and check the gas
pressure in balancing mode.
Checking the power module.
The compressor is defective. Replace it
and seal refrigerant.
If the compressor checker for an
inverter type air conditioner is
available, re-check using it.
Gas leaks.
Repair and seal refrigerant.
Perform a final check of operation.
YES
Gas leaking
Lighting mode
Blinks
2 times
Blinks
3 times
Blinks
4 times
Blinks
5 times
Blinks
6 times
Blinks
8 times
LD301
Approx. 10 seconds
Compressor
Blinking Off
Time until the
lamp lights
Possible
malfunctioning
part
Approx.
10
seconds
Approx.
10
seconds
Within
approx.
30
minutes
Gas
leakage
Compressor
Self・
diagnosis Lamp
Outdoor
unit
Manifold
valve
When the
self-diagnosis lamp
lights in the same
condition as above.
Normal
(JUDGING BETWEEN GAS LEAKAGE AND COMPRESSOR DEFECTIVE)
Mpa(G){kgf/cm
2
(G)
Chargeportpressure