HOW TO CHANGE THE INTERMITTENT FAN HEATING SETTING
Default : Pattern 1
Pattern 3Pattern 1 Pattern 2
The intermittent fan control during thermo in Heating mode can be changed by the remote controller.
(The procedure should be done only by service personnel.)
It is possible to select from 3 patterns.
PROCEDURE
Press (POWERFUL) button, (FAN SPEED) button and press [RESET] butt on simultaneously.
Release [RESET] button only and make sure that all marks on the remote controller display are indicated, then release
(POWERFUL) button and (F
AN SPEED) button.
Remote controller now enters Intermittent Fan Control Change Mode.
Press [ROOM TEMPERATURE setting] [ (UP) / (DOWN)] button.
(The intermittent pattern changed with indoor unit beep sound)
Transmission sign lights up with beep from indoor unit simultaneously.
Pattern 3 Pattern 2 Pattern 1
Single model Continuous
30sec ON / 210sec OFF
repeatedly
50sec ON / 190sec OFF
repeatedly
Multi
30sec ON / 210sec OFF
repeatedly
50sec ON / 190sec OFF
repeatedly
Continuous
NOTE:
(1) The indication of the selected intermittent pattern will disappear after 10 seconds.
(2) The selected intermittent pattern will remain unchanged after the unit is truned o˜.