Capacity | 1.5 Ton |
---|---|
Cooling Capacity | 5.0 kW |
Heating Capacity | 5.5 kW |
Refrigerant | R410A |
Coefficient of Performance (COP) | 3.8 |
Type | Split |
Power Supply | 230V, 50Hz, 1 Phase |
Noise Level (Indoor) | 42 dB |
Noise Level (Outdoor) | 52 dB |
Specifications for RAK-18RPD, RAK-25RPD, and RAK-35RPD indoor units.
Specifications for RAK-42RPD and RAK-50RPD indoor units.
Specifications for RAC-18WPD, RAC-25WPD, and RAC-35WPD outdoor units.
Specifications for RAC-42WPD and RAC-50WPD outdoor units.
Dimensional data for RAK/RAC 18/25/35/42/50RPD/WPD wall type indoor units.
Dimensional data for RAC-18WPD, RAC-25WPD, and RAC-35WPD outdoor units.
Dimensional data for RAC-42WPD and RAC-50WPD outdoor units.
Charts showing cooling and heating capacity characteristics based on ambient temperature.
Factors to adjust cooling and heating capacity based on piping length and configuration.
Factors to adjust heating capacity considering defrosting cycles and white frost.
Sound data for the RAC-18WPD outdoor unit across various octave bands.
Sound data for the RAC-25WPD outdoor unit across various octave bands.
Sound data for the RAC-35WPD outdoor unit across various octave bands.
Sound data for the RAC-42WPD outdoor unit across various octave bands.
Sound data for the RAC-50WPD outdoor unit across various octave bands.
Details on the required power supply voltage and imbalance tolerance for the units.
Operating temperature ranges for cooling and heating modes for indoor and outdoor units.
Electrical specifications including voltage, current, and fan motor data for indoor units.
Electrical specifications for outdoor units including compressor and fan motor data.
Wiring diagram for RAK-18RPD, RAK-25RPD, RAK-35RPD, RAK-42RPD, RAK-50RPD indoor units.
Wiring diagram for RAC-18WPD, RAC-25WPD, and RAC-35WPD outdoor units.
Wiring diagram for RAC-42WPD and RAC-50WPD outdoor units.
Refrigerant cycle schematic for RAK/RAC 18/25/35 WPD/RPD wall type units.
Refrigerant cycle schematic for RAK/RAC 42/50 WPD/RPD wall type units.
Overview of functions and buttons available on the wireless remote controller.
Explanation of how the unit automatically switches between cooling and heating modes.
Procedure for adjusting temperature shift values for heating or cooling modes.
Instructions on how to lock and unlock heating, cooling, and dehumidifying modes.
Procedure to prevent remote control interference between multiple indoor units.
Setting intermittent fan speed control during thermo-off in heating mode.
Details on additional functions configurable via indoor unit DIP switches.
Information and operation of the SPX-RCDB wired remote controller.
List of error codes displayed on the wired remote controller and their meanings.
Procedure for adjusting shift values using the wired remote control.
Safety summary and installation details for the H-Link Adaptor.
System configuration and wiring guidelines for H-Link adaptor connections.
Configuration of DIP switches on the RAC adaptor for various settings.
Procedure for performing a test run after installation and setting of RAC adaptor.
Using the Dry Contact system with DIP switches for external control integration.
Information on using the SPX-DST1 distributor for centralized control of multiple units.