EasyManua.ls Logo

Hitachi RAK-18RPD User Manual

Hitachi RAK-18RPD
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL CATALOGUE
MONO SPLIT
RAK-18RPD
RAK-25RPD
RAK-35RPD
RAK-42RPD
RAK-50RPD
RAC-18WPD
RAC-25WPD
RAC-35WPD
RAC-42WPD
RAC-50WPD

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAK-18RPD and is the answer not in the manual?

Hitachi RAK-18RPD Specifications

General IconGeneral
Capacity1.5 Ton
Cooling Capacity5.0 kW
Heating Capacity5.5 kW
RefrigerantR410A
Coefficient of Performance (COP)3.8
TypeSplit
Power Supply230V, 50Hz, 1 Phase
Noise Level (Indoor)42 dB
Noise Level (Outdoor)52 dB

Summary

Specifications

Wall Type RAK-18RPD/25RPD/35RPD Specifications

Specifications for RAK-18RPD, RAK-25RPD, and RAK-35RPD indoor units.

Wall Type RAK-42RPD/50RPD Specifications

Specifications for RAK-42RPD and RAK-50RPD indoor units.

Wall Type RAC-18WPD/25WPD/35WPD Specifications

Specifications for RAC-18WPD, RAC-25WPD, and RAC-35WPD outdoor units.

Wall Type RAC-42WPD/50WPD Specifications

Specifications for RAC-42WPD and RAC-50WPD outdoor units.

Dimensional Data

Wall Type Dimensional Data

Dimensional data for RAK/RAC 18/25/35/42/50RPD/WPD wall type indoor units.

RAC-18WPD/25WPD/35WPD Dimensional Data

Dimensional data for RAC-18WPD, RAC-25WPD, and RAC-35WPD outdoor units.

RAC-42WPD/50WPD Dimensional Data

Dimensional data for RAC-42WPD and RAC-50WPD outdoor units.

Capacities Table

Capacity Characteristic Curves

Charts showing cooling and heating capacity characteristics based on ambient temperature.

Correction Factors for Piping Length

Factors to adjust cooling and heating capacity based on piping length and configuration.

Correction Factors for Defrosting Operation

Factors to adjust heating capacity considering defrosting cycles and white frost.

Sound Data

RAC-18WPD Sound Data

Sound data for the RAC-18WPD outdoor unit across various octave bands.

RAC-25WPD Sound Data

Sound data for the RAC-25WPD outdoor unit across various octave bands.

RAC-35WPD Sound Data

Sound data for the RAC-35WPD outdoor unit across various octave bands.

RAC-42WPD Sound Data

Sound data for the RAC-42WPD outdoor unit across various octave bands.

RAC-50WPD Sound Data

Sound data for the RAC-50WPD outdoor unit across various octave bands.

Working Range

Power Supply Requirements

Details on the required power supply voltage and imbalance tolerance for the units.

Unit Working Temperature Range

Operating temperature ranges for cooling and heating modes for indoor and outdoor units.

Electrical Data

Indoor Unit Electrical Data

Electrical specifications including voltage, current, and fan motor data for indoor units.

Outdoor Unit Electrical Data

Electrical specifications for outdoor units including compressor and fan motor data.

Wiring Diagram

RAK Indoor Unit Wiring Diagram

Wiring diagram for RAK-18RPD, RAK-25RPD, RAK-35RPD, RAK-42RPD, RAK-50RPD indoor units.

RAC-18/25/35WPD Wiring Diagram

Wiring diagram for RAC-18WPD, RAC-25WPD, and RAC-35WPD outdoor units.

RAC-42/50WPD Wiring Diagram

Wiring diagram for RAC-42WPD and RAC-50WPD outdoor units.

Refrigerant Cycle

Refrigerant Cycle for RAK/RAC 18/25/35 WPD/RPD

Refrigerant cycle schematic for RAK/RAC 18/25/35 WPD/RPD wall type units.

Refrigerant Cycle for RAK/RAC 42/50 WPD/RPD

Refrigerant cycle schematic for RAK/RAC 42/50 WPD/RPD wall type units.

Control and Function

Wireless Remote Control Function

Overview of functions and buttons available on the wireless remote controller.

Auto Changeover Function

Explanation of how the unit automatically switches between cooling and heating modes.

Shift Value Adjustment

Procedure for adjusting temperature shift values for heating or cooling modes.

Operation Lock Function

Instructions on how to lock and unlock heating, cooling, and dehumidifying modes.

Prevention of Mutual Interference

Procedure to prevent remote control interference between multiple indoor units.

Intermittent Fan Speed Setting

Setting intermittent fan speed control during thermo-off in heating mode.

Additional Functions via DIP-Switch Settings

Details on additional functions configurable via indoor unit DIP switches.

Option List

Wired Remote Control SPX-RCDB

Information and operation of the SPX-RCDB wired remote controller.

Wired Remote Error Code Information

List of error codes displayed on the wired remote controller and their meanings.

Wired Remote Shift Value Adjustment

Procedure for adjusting shift values using the wired remote control.

H-Link Adaptor PSC 6RAD

Safety summary and installation details for the H-Link Adaptor.

H-Link Adaptor Electrical Wiring

System configuration and wiring guidelines for H-Link adaptor connections.

H-Link Adaptor DIP Switch Setting

Configuration of DIP switches on the RAC adaptor for various settings.

H-Link Adaptor Test Run

Procedure for performing a test run after installation and setting of RAC adaptor.

Dry Contact Application SPX-WDC3

Using the Dry Contact system with DIP switches for external control integration.

Distributor SPX-DST1

Information on using the SPX-DST1 distributor for centralized control of multiple units.

Related product manuals