10.1. WIRED REMOTE CONTROL – SPX-RCDB 
10.1.1.  SHIFT VALUE 
1. Press and hold   (ON/OFF) button and  (ON TIMER) button at the same time while giving a single press on 
the RESET button until remote controller now enter ‘Shift value change mode’. 
2. Press  (ON/OFF) button so that the display indicates  (FAN) speed. 
3. Select  (FAN SPEED) button to choose Heating Shift or Cooling Shift Mode.
or MED  , it will go to Cooling Shift mode. By setting fan speed to HIGH 
By setting fan speed to LOW   or SILENT , it will go to Heating Shift mode. 
4. Press
5. Press
 (ROOM TEMPERATURE) button to change the shift value (-3°C ~ 0 ~ 3°C). 
 (ON/OFF) button to end ‘Shift value setting mode’. 
NOTE: 
1. There are total of 7 shift values ranging from -3 to 3.
2. The changed shift value will remain unchanged after turned off the power.
RAR-5G2 (SPX-RCDB) 
BUTTONS  FUNCTION 
MODE Selector 
Use this button to select the operationg mode. Every time you press this button, 
the mode will change from 
 cyclically. 
FAN SPEED Selector Button 
This determines the fan speed. Every time you press this button, the airflow 
rate will change from 
 (This button allows selection of optimal or preferred fan speed for 
each operation mode). 
ON/OFF button 
Press this button to start operation. Press it again to stop operation. 
SLEEP button 
Use this button to set the SLEEP timer. 
SET button 
Timer setting reservation. 
OFF button 
Select the turn OFF timer. 
ON button 
Select the turn ON timer. 
CANCEL button 
Cancel timer reservation. 
AUTO SWING (Vertical) button 
Controls the angle of the horizontal air deflector. 
ROOM TEMPERATURE setting button 
Value will change quicke when keep pressing.