CONTROL AND FUNCTION
9.8.  ERROR CODE INFORMATION 
1. In case failure occurs to the air conditioner, by pressing (INFO) button, an error code will be displayed. 
2. Direct the remote controller towards the receiver of indoor unit (within 2 meters in from of indoor unit) and press
 (INFO) button. 
3. Wait for 2 seconds for signal transmission and the error code will be displayed.
TIMER LAMP BLINKING  LED301 
BLINKING 
CODE  MEANING 
INDOOR 
-  - 
000 
00 
Normal 
1 time 
001 
00 
Refrigerant cycle fault 
2 times  -  -  Outdoor unit is under forced operation 
3 times  9 times 
003 
00 
Communication error between indoor and outdoor 
units 
9 times  - 
009 
00 
Indoor thermistor 
10 times  - 
010 
00 
Abnormal rotating numbers 
13 times  - 
013 
00 
IC401 data reading error 
OUTDOOR 
4 times  2 times 
002 
01 
Peak current cut 
4 times  3 times 
003 
01 
Compressor abnormal low speed rotation 
4 times  4 times 
004 
01 
Compressor switching failure 
4 times  5 times 
005 
01 
Overload lower limit cut 
4 times  6 times 
006 
01 
OH thermistor temperature rise 
4 times  7 times 
007 
01 
Abnormal outdoor thermistor 
4 times 
16 times 
016 
01 
Hign load stop
4 times  9 times 
009 
01 
Communication error 
4 times  10 times 
010 
01 
Abnormal power source 
4 times  11 times 
011 
01 
Fan stop for strong wind 
4 times  12 times 
012 
01 
Fan motor fault 
4 times  13 times 
013 
01 
EEPROM reading error 
4 times  14 times 
014 
01 
Active converter defective 
4 times  15 times 
015 
01 
Abnormal PWB circuit 
12 times 
- 
012 
00 
Communication error between indoor and outdoor 
units