1. Front panel
MODEL RAK-25/35/50PSEW, RAK-25/35/50PSES
Open Range: 0° to 60°
PROCEDURE FOR DISASSEMBLY AND REASSEMBLY
(1) Open the front panel
(2) After removing 1 screw with a short screw driver,
remove the Temperature Display box.
• Hold the lower of the front panel with both hands.
• If it is raised further, the front panel may be damaged.
Screw
(3) Remove the front panel.
2.Fancy cover
(1) Unscrew the terminal board cover and the fancy cover.
(2) Remove the terminal board cover and dust box.
(3) Pull the center of the front cover towards you and release
the claw in the middle.
1.Push the end of the right-side arm outward to release
the tab.
2.Move the left-side arm outward to release the left tab,
and then pull the panel towards you.
PUSH
Arm
Arm
Screw
Terminal
cover
Lower cover
Release the 3 claws on top of front cover and 2 claws in
front, remove the front cover toward the direction as
illustrated.
Dust box
Screw
Screw
The claws in front
The Claw in the middle
The claw on top of the front cover (the back of the front cover)
The claw on top of the front cover
The claw on top of
the front cover