(1) Remove the dust catcher as shown with arrows.
If dust is accumulated at the inner side of the dust catcher,
remove the dust with a vacuum cleaner.
Remove the lead wrie and ground wire from the electrical
parts box(CN8,CN10).
(2) Release the lower claws(x 3) and put your hand into the
left side of the dust catcher,pull the bottom slightly
upwords,then remove it towards you,and remove the
cleaning unit.
(1) Press the hook lug of the electrical parts lid and remove
the lid.
(2) From the control P.W.B., remove the lead wires fixed to
the electrical parts box.
(3) Remove the screw that fixes the ground wire to the
electrical patrs box.
(4) Push the Control P.W.B slightly towards the right-side
and remove the Control P.W.B.
(1) From the FC-guide frame,remove the lead wire.
(2) Press the FC-guide frame fixed claw right side.
Remove the ECO sensor from the rear.
3. Cleaning unit
4. Control P.W.B. components
5. ECO sensor
ground wire screw
6. The dust catcher
7. Tangential air flow fan and fan motor
Attach the dust catcher
Hold the dust catcher for the top face with its side having the
lever facing towards you. Insert and push in the dust catcher
in the arrow direction until it clicks.
1
2
1
2
Hole
Hold the dust catcher for the top face
Claw
Claw
(1) Loosen the fan lock screw.
(2) Press the fan motor cover 2 fixed pawl, and
remove from the right to.