EasyManua.ls Logo

Hitachi RAM-65QH4 - User Manual

Hitachi RAM-65QH4
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
RAM-55QH4
RAM-65QH4
NO. 0217E
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT
ROOM AIR CONDITIONER
OUTDOOR UNIT
JUNE 2004
Refrigeration & Air-Conditioning Division
SERVICE MANUAL
PM
REFER TO THE FOUNDATION MANUAL
TECHNICAL INFORMATION
FOR SERVICE PERSONNEL ONLY
CONTENTS
SPECIFICATIONS ------------------------------------------------------------------- 5
INSTALLATION ---------------------------------------------------------------------- 14
CONSTRUCTION AND DIMENSIONAL DIAGRAM ---------------------- 21
MAIN PARTS COMPONENT --------------------------------------------------- 23
CAPACITY DIAGRAM ------------------------------------------------------------- 25
WIRING DIAGRAM ----------------------------------------------------------------- 33
CIRCUIT DIAGRAM ---------------------------------------------------------------- 37
BLOCK DIAGRAM ------------------------------------------------------------------43
BASIC MODE ------------------------------------------------------------------------ 45
REFRIGERATING CYCLE DIAGRAM ---------------------------------------- 73
DESCRIPTION OF MAIN CIRCUIT OPERATION ------------------------ 77
TROUBLE SHOOTING ---------------------------------------------------------- 108
DISASSEMBLY AND REASSEMBLY --------------------------------------- 115
PARTS LIST AND DIAGRAM ------------------------------------------------- 118
RAM-55QH4
RAM-65QH4
After installation
NOTE:
This manual describes only points that differ from RAF-25,
50NH4, RAD-25, 40QH4 and RAM-70, 80QH4 (TC No.
0757EF), RAK-25, 35, 50NH4 (TC No. 0761EF), RAD-25,
40NH4, RAI-25, 40NH4 (TC No. 0763EF) for items not
described in this manual.
850
650
298
50
(W)
(A)
COOLING CAPACITY
DC INVERTER DUAL SYSTEM MULTI
TYPE
MODEL
POWER SOURCE
TOTAL INPUT
TOTAL AMPERES
SPECIFICATIONS
OUTDOOR UNIT
RAM-55QH4
RAM-65QH4
HEATING CAPACITY
DIMENSIONS (mm)
NET WEIGHT
1ø, 220 - 240V, 50Hz
W
H
D
(kg)
(kW)
(B.T.U.)
REFER TO THE SPECIFICATIONS PAGE

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAM-65QH4 and is the answer not in the manual?

Summary

SAFETY DURING REPAIR WORK

WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS

Items to be observed in handling

Guidelines for safely handling semiconductor components and preventing damage during maintenance.

INSTALLATION

PIPE LENGTH

Specifies the maximum allowable lengths for refrigerant piping between indoor and outdoor units.

HIGHT DIFFERENCE

Defines the permissible vertical height differences between indoor and outdoor units for proper operation.

DESCRIPTION OF MAIN CIRCUIT OPERATION

8. Overload control circuit (OVL control circuit)

Explanation of the overload control system and its methods for preventing compressor damage.

INSPECTING OUTDOOR ELECTRICAL PARTS

TROUBLE SHOOTING

Summary

SAFETY DURING REPAIR WORK

WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS

Items to be observed in handling

Guidelines for safely handling semiconductor components and preventing damage during maintenance.

INSTALLATION

PIPE LENGTH

Specifies the maximum allowable lengths for refrigerant piping between indoor and outdoor units.

HIGHT DIFFERENCE

Defines the permissible vertical height differences between indoor and outdoor units for proper operation.

DESCRIPTION OF MAIN CIRCUIT OPERATION

8. Overload control circuit (OVL control circuit)

Explanation of the overload control system and its methods for preventing compressor damage.

INSPECTING OUTDOOR ELECTRICAL PARTS

TROUBLE SHOOTING

Hitachi RAM-65QH4 Specifications

General IconGeneral
BrandHitachi
ModelRAM-65QH4
CategoryAir Conditioner
LanguageEnglish

Related product manuals