– 76 –
初回
Mold monitoring
Monitor lamp
Operation lamp
Indoor unit
Vertical vane
Dehumidification
Humidity
3-minute
SS
tuhStuhS
Dehumidification position
Lo in dehumidification
First time
20 minutes
3-minute
SS
20 minutes
3-minute
SS
20 minutes
3-minute
SS
Dehumidification position
Second time
Lo in dehumidification
Setting "mold monitoring" will activate the product as follows:
(1) The indoor unit will be operated for 3 minutes to detect the temperature and
humidity.
(2) When the temperature
10 and the humidity
70%, the product will
perform dehumidification (4 hours). If it deviates from the conditions,
it will stop for 20 minutes.
(3) After the product runs for 4 hours, it will stop for 20 minutes.
(4) The indoor unit is run for 3 minutes to detect the temperature and humidity.
(5) In second and subsequent mold monitoring operations, and if the temperature
10 and the humidity
70%, the product will begin dehumidification again.
If the product deviates from the conditions, it will stop for 20 minutes.
(6) When the humidity
60%, the product will stop.
(7) After the product stops for 20 minutes, it will go back to (4).