Models
<Indoor Units>
In-the-Ceiling Type
RPI-0.8FSG1 RPI-2.5FSG1 RPI-8FSG1
RPI-1.0FSG1 RPI-3.0FSG1 RPI-10FSG1
RPI-1.5FSG1 RPI-4.0FSG1
RPI-2.0FSG1 RPI-5.0FSG1
4-Way Cassette Type
RCI-1.0FSG2 RCI-2.5FSG2 RCI-5.0FSG2
RCI-1.5FSG2 RCI-3.0FSG2
RCI-2.0FSG2 RCI-4.0FSG2
2-Way Cassette Type
RCD-1.0FSG1 RCD-2.5FSG1 RCD-5.0FSG1
RCD-1.5FSG1 RCD-3.0FSG1
RCD-2.0FSG1 RCD-4.0FSG1
•Wall Type
RPK-1.0FSGM6 RPK-2.0FSGM6
RPK-1.5FSGM6 RPK-2.3FSGM6
Floor Type
RPF-1.0FSG(E) RPF-1.5FSG(E)
Floor Concealed Type
RPFI-1.0FSG(E) RPFI-1.5FSG(E)
Ceiling Type
RPC-2.0FSG1 RPC-3.0FSG1 RPC-5.0FSG1
RPC-2.5FSG1 RPC-4.0FSG1
<Outdoor Units>
FSG(1) Series
RAS-5FSG RAS-16FSG RAS-24FSG1
RAS-8FSG RAS-20FSG RAS-30FSG1
RAS-10FSG
•FS3, FS5 Series
RAS-5FS3 RAS-16FS3 RAS-24FS5
RAS-8FS3 RAS-20FS3 RAS-30FS5
RAS-10FS3
FXG Series
RAS-8FXG RAS-10FXG
FX3 Series
RAS-8FX3 RAS-10FX3
<System Equipment>
•Total Heat Exchangers
KPI-2521 KPI-5021 KPI-8021 KPI-10021
This service mamual provides the technical
information for the HITACHI Inverter-Driven
Multi-Split System Heat Pump Air
Conditioners, “SET FREE, FSG(1)/FS3, FS5
and FXG/FX3 Series”.
Read this manual carefully before starting
service activities.
HITACHI INVERTER-DRIVEN
MULTI-SPLIT SYSTEM
HEAT PUMP AIR CONDITIONERS
SET FREE FSG(1)/FS3, FS5 SERIES
AND
SET FREE FXG/FX3 SERIES
P5413553

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAS-10FS3 and is the answer not in the manual?

Hitachi RAS-10FS3 Specifications

General IconGeneral
BrandHitachi
ModelRAS-10FS3
CategoryAir Conditioner
LanguageEnglish

Summary

TROUBLESHOOTING

Initial Troubleshooting

Covers basic checks like switch settings, wiring, and displays for troubleshooting.

Troubleshooting Procedure

Details methods for diagnosing issues using alarm codes and check modes.

Procedure of Checking Each Main Parts

Explains how to self-check PCBs, remote controls, and other key components.

Test Run

Provides procedures for running tests on units via remote control or outdoor unit.

SERVICING

Outdoor Unit

Covers procedures for disassembling and servicing outdoor unit components.

In-the-Ceiling Type

Details servicing steps specific to RPI series in-ceiling units.

4-Way Cassette Type

Outlines disassembly and servicing procedures for 4-way cassette indoor units.

2-Way Cassette Type

Outlines disassembly and servicing procedures for 2-way cassette indoor units.

Wall Type

Details disassembly and servicing procedures for wall-mounted indoor units.

Floor Type

Outlines disassembly and servicing procedures for floor-standing indoor units.

Floor Concealed Type

Details disassembly and servicing procedures for floor-concealed indoor units.

Ceiling Type

Outlines disassembly and servicing procedures for ceiling-mounted indoor units.

Total Heat Exchanger

Covers structure and removal of electrical parts for total heat exchangers.

Cleaning Indoor Unit Heat Exchanger

Provides instructions and tools for cleaning indoor unit heat exchangers.

Collecting Refrigerant for Replacing Indoor Unit

Details the procedure for safely collecting refrigerant before unit replacement.

MAIN PARTS

Inverter

Covers inverter specifications, protection functions, and overload control.

AC Chopper

Explains the concept, features, and specifications of AC chopper control.

Auto-Louver Mechanism

Details the operation and stoppage principles of auto-louver mechanisms.

Scroll Compressor

Explains the structure, mechanism, and principle of scroll compressors.

Thermistor

Lists thermistor positions and resistance characteristics for indoor and outdoor units.

Electronic Expansion Valve

Provides specifications and diagrams for electronic expansion valves.

Pressure Sensor

Explains high and low pressure control mechanisms and sensor characteristics.

High Pressure Protection Device

Details the function and circuit of the high pressure protection device.

Noise Filter (NF)

Explains the purpose and specifications of noise filters.

Capacitor (CB1, CB2)

Lists specifications for capacitors used in the inverter.

Reactor (DCL)

Lists specifications for reactors used in the inverter.

OPTIONAL FUNCTION

Indoor Unit

Covers remote control functions, power supply settings, and thermostat control for indoor units.

Indoor Unit

Details input/output settings, unit selection, and remote control thermistor function for indoor units.

Outdoor Unit

Explains external signal inputs and outputs for outdoor units like demand and forced stoppage.

Remote Control Switch, PC-P1H and PC-2H2

Describes the parts and functions of remote control switches PC-P1H and PC-2H2.

Wireless Remote Control Switch, PC-LH3

Details the parts and identification procedures for wireless remote control switches.

7-Day Timer, PSC-5T

Explains the operation and indicators of the 7-day timer.

Central Station, PSC-5S

Describes the features and operation of the central station unit.

FIELD WORK INSTRUCTION

Burnt-out Compressor due to Insufficient Refrigerant Charge

Analyzes compressor burnout caused by low refrigerant charge and provides solutions.

Insufficient Cooling Performance When A Long Piping Is Applied

Addresses cooling issues related to long piping installations and required settings.

Abnormally High Operating Sound [In-the-Ceiling Type Indoor Unit]

Investigates causes and countermeasures for high operating sound in ceiling units.

Alarm Code “31”

Explains the cause and countermeasures for Alarm Code "31".

Not Cooling Well due to Insufficient Installation Space for Outdoor Unit

Discusses cooling issues arising from inadequate outdoor unit installation space.

Attention for SET-FREE FXG/FX3 Series

Highlights important considerations for system design and installation of SET-FREE FXG/FX3 series.

Select Guide of Drain Pipe for Indoor Unit

Provides guidelines for selecting appropriate drain pipe diameters based on flow volume.

Caution on Refrigerant Leakage

Details maximum permissible refrigerant concentrations and countermeasures for leaks.

Maintenance Work

Outlines routine maintenance checks for indoor and outdoor units, compressors, and electrical parts.

ELECTRICAL WIRING DIAGRAMS

ELECTRIC WIRING DIAGRAM (For Models: RAS-8FXG and RAS-10FXG)

Shows electrical wiring diagrams for RAS-8FXG and RAS-10FXG models.

ELECTRIC WIRING DIAGRAM (For Models: CH-4.0GE and CH-6.5GE)

Illustrates electrical wiring for CH-4.0GE and CH-6.5GE models.

CONTROL SYSTEM

REFRIGERANT CYCLE (EXAMPLE: RAS-10FXG)

Depicts the refrigerant cycle for the RAS-10FXG model, showing key components.