Ð4Ð
 
 
To prevent dust from coming into the indoor unit.
(Refer page 16)
 
  
Light indicator showing the operating condition.
(Refer page 5)
   
 
(Refer page 15)
 
Send out operation signal to the indoor unit. So as
to operate the whole unit.
(Refer page 6)
   !!
 
 
When ÒheatingÓ operation is
performed, cool air blows
and when ÒcoolingÓ or
ÒdehumidifyingÓ operation is
performed, warm air blows.
 "
Drains the dehumidified water from the indoor unit to the outdoor
during ÒcoolingÓ or ÒdehumidifyingÓ operation.
#$  %$
     
& "  '
¥When ÒStopÓ is selected during operation of the indoor
unit, the fan of the outdoor unit continues turning for
10 to 60 seconds to cool the electric parts down.
¥Inheating operation, condensate or water due to
defrosting will flow.
Do not cover the drain port of the outdoor unit because
such water may freeze in the chilly area.
¥When the outdoor unit is hung on the ceiling, install
the bush and drain pipe on the drain port and drain
water.
 
(
" 
 )   " 
MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm)
RAS-18YH5, RAS-25YH5, RAS-35YH5 780 280 210
RAC-18YH5, RAC-25YH5, RAC-35YH5 750 548 288
!  *!  * #
Ð5Ð
 # $
This lamp lights when the timer is working.
  # +
When the device is operated for a total of about 200
hours, the FILTER lamp lights indicates that it is time
to clean the filter.The lamp goes out when the
Ò
(AUTO SWING)Ó button is pressed while the
operation is stopped.
# # ,)
This lamp lights during operation.
The OPERATION LAMP flashes in the following
cases during heating.
- $ "$
For about 2-3 minutes after starting up.
. $ $
Defrosting will be performed about once an hour
when frost forms on the heat exchanger of the
outdoor unit, for 5-10 minutes each time.
#, !%*
Use this switch to start and stop when the remote controller does not work.
This temporary operation will be at the most recent setting made. (The unit
will immediately go into automatic operation once power is switched on.)
*
Turn off the circuit breaker or pull out
the power plug if the unit is not be
operated for a long period.
If the power stays on and the unit is not operated, power is slightly consumed in the control circuit.
The power is saved by turning off the power switch (or the circuit breaker when the power is supplied
from the outdoor unit).
"$ "  $  $    "  /
¥ Attach the air cleansing and deodorizing filters to the frame by
gently compress its both sides and release after insertion into
filter frame.
¥ The cooling capacity is slightly weakened and the cooling speed
becomes slower when the air cleansing and deodorizing filters
are used.
¥ Air cleansing and deodorizing filters are washable and reusable up to 20 times by using vacuum
cleaner or water rinse under running tap water.When you want to renew it, please ask your sales
agent.
Frame
#% !%*
  *!
– 6 –