2 Unit Installation
23
SMGB0064 rev.0 - 08/2011
2
Recommended Metal Plate Size
• (Field-Supplied) Material: Hot-Rolled Mild Steel.
• Plate (SPHC) Plate Thickness: 4.5 T.
Example of xing outdoor unit by anchor bolts
1. Max. 21 mm (After cut “A”)
2. Concrete
3. Anchor bolt
B. Cut this portion when this type of anchor bolt is used. If not done
it will be dicult to remove the service cover
B
1
2
3
Fix unit to the wall
1 Fix the unit onto the wall as shown in the gures (Field supplied bracket).
2 Secure the foundation to avoid noise and warping
3 To avoid vibrations transferring to the building use a rubber mat.
RAS-3HVRNM2E RAS-(4-6)H(V)RNM2E
RAS-(4-6)H(V)RNS2E RAS-(8-12)HRNM
RAS-(8/10)HRNSE
A
1
2
*
2
1
1. Rubber material
2. Fixing plate
N O T E
• (*): In RAS-(8-12)HRNM are 110 mm
Model RAS-3HVRNM2E RAS-(4-6)H(V)RNS2E RAS-(4-6)H(V)RNM2E RAS-(8-12)HRNM RAS-(8/10)HRNSE
A (mm) 529 796 529 1173 1109