2āāFeaturesāandābeneīæts
Eco-DesingāandāSeasonalāEfīæciency
TCGB0136 rev.1 - 05/2021
20
Seasonal Energy Efīæciency Ratio (SEER)āinācoolingāandātheāSeasonal Coefīæcient of Performance (SCOP) in
heatingāgiveāaāmoreāaccurateāestimationāofātheārealāperformanceāofātheāequipmentāduringātheāwholeāperiodāofāusage,āallā
whileāconsidering:
ā¢ā Severalāpointsāofāmeasureā(Inācoolingāmode:āanāoutsideātemperatureāofā20ĀŗC,ā25ĀŗC,ā30ĀŗCāandā35ĀŗC;āināheatingāmode:ā
anāoutsideātemperatureāofā+12ĀŗC,ā+7ĀŗC,ā+2ĀŗC,āandā-7ĀŗC.
ā¢ā Differentācompressorāspeedsā(fullāloadāandāpartialāload),āauxiliaryāconsumptionā(crankcaseāheaters,āthermostatāoffā
mode,āOFFāmodeā¦).
ā¢ā Conditionsāofātemperatureā(numberāofāhoursāperāoutdoorātemperature)āforāanāidentiīæedāclimateā(averageāclimateāforā
ErPācompliance)
ā¢ā Buildingāheatāloadā(calledāPdesign)
Hitachi,āinācomplianceāwithātheāEcoāDesignāDirective,āhasādevelopedātheānewāoutdoorāunits:ānewāUTOPIAāseries,āwhoseā
highāefīæciencyālevelā(includingāSEERāandāSCOPāvalues)āisāproperlyāinformedātoāourācustomersātoāallowāforāanāeasyā
selection.
NewāUTOPIAāseriesāofferāhighāseasonalāefīæciencies,āasāwellāasācompleteāīexibility,āwithāallāoutdoorāunitsāfromābothārangesā
beingāfullyācompatibleāwithātheāSystemāFreeārangeāofāindoorāunits.āHitachiāsāUTOPIAātechnologyāhasāallātheābeneīætsāofā
VRF,āincludingāindividualācontrolāofāeachāindoorāunitāwithāanāincreasedānumberāofāindoorāunitācombinationsāināadditionātoā
deliveringāexcellentāpart-loadāefīæciency.
Withācoolingācapacitiesāandāheatingācapacitiesāfromā2HPātoā12HP,āaāmaximumāofā4āindoorāunitsāareāconnectableā
toāaāsingleāoutdoorāunit,āwithāindividualācontrolāandāefīæcienciesāachievedāasāhighāasāA++/A+ā(dependingāonāmodel/
combinations).
2.2.3 Energy classes and energy label (Lot 10)
Theāenergy efīæciencyāclassesāfromāA+++ātoāDāareāintroducedābasedāonāSCOPāandāSEERāvalues:āTheāscaleāforāenergyā
labellingāis:
A+++
A++
D
C
B
A
A+
E
F
G SCOP < 1,90
1,90SCOP< 2,20ā¤
2,20SCOP< 2,50ā¤
2,50SCOP< 2,80ā¤
2,80SCOP< 3,10ā¤
3,10SCOP< 3,40ā¤
3,40SCOP< 4,00ā¤
4,00SCOP< 4,60ā¤
4,60SCOP< 5,10ā¤
SCOP 5,10ā„
5,60SEER < 6,10ā¤
6,10SEER < 8,50ā¤
SEER 8,50ā„
5,10SEER < 5,60ā¤
4,60SEER < 5,10ā¤
4,10SEER < 4,60ā¤
3,60SEER < 4,10ā¤
3,10SEER < 3,60ā¤
2,60SEER < 3,10ā¤
SEER < 2,60
TheāEnergy labelāisātheāregulationācompliantāwayāofādisplayingāproductāefīæciencyāandāsoundālevelātoāanyāpointāofāsales.ā
Thisālabelādisplaysā3āEuropeanāclimates:āaverageāclimateā(green),ācoldāclimateā(blue),āhotāclimateā(orange).āRegulationā
requirementāisātoādisplayāanyāinformationārelatedātoāperformancesāonāaverageāclimate.
Climate used on ErP Temperature used for product selection
Average -10°C
Cold -22°C
Hot +2