2ā€ˆā€ˆFeaturesā€ˆandā€ˆbenets
Eco-Desingā€ˆandā€ˆSeasonalā€ˆEfciency
TCGB0136 rev.1 - 05/2021
20
Seasonal Energy Efciency Ratio (SEER)ā€ˆinā€ˆcoolingā€ˆandā€ˆtheā€ˆSeasonal Coefcient of Performance (SCOP) in
heatingā€ˆgiveā€ˆaā€ˆmoreā€ˆaccurateā€ˆestimationā€ˆofā€ˆtheā€ˆrealā€ˆperformanceā€ˆofā€ˆtheā€ˆequipmentā€ˆduringā€ˆtheā€ˆwholeā€ˆperiodā€ˆofā€ˆusage,ā€ˆallā€ˆ
whileā€ˆconsidering:
ā€¢ā€ˆ Severalā€ˆpointsā€ˆofā€ˆmeasureā€ˆ(Inā€ˆcoolingā€ˆmode:ā€ˆanā€ˆoutsideā€ˆtemperatureā€ˆofā€ˆ20ĀŗC,ā€ˆ25ĀŗC,ā€ˆ30ĀŗCā€ˆandā€ˆ35ĀŗC;ā€ˆinā€ˆheatingā€ˆmode:ā€ˆ
anā€ˆoutsideā€ˆtemperatureā€ˆofā€ˆ+12ĀŗC,ā€ˆ+7ĀŗC,ā€ˆ+2ĀŗC,ā€ˆandā€ˆ-7ĀŗC.
ā€¢ā€ˆ Differentā€ˆcompressorā€ˆspeedsā€ˆ(fullā€ˆloadā€ˆandā€ˆpartialā€ˆload),ā€ˆauxiliaryā€ˆconsumptionā€ˆ(crankcaseā€ˆheaters,ā€ˆthermostatā€ˆoffā€ˆ
mode,ā€ˆOFFā€ˆmode…).
ā€¢ā€ˆ Conditionsā€ˆofā€ˆtemperatureā€ˆ(numberā€ˆofā€ˆhoursā€ˆperā€ˆoutdoorā€ˆtemperature)ā€ˆforā€ˆanā€ˆidentiedā€ˆclimateā€ˆ(averageā€ˆclimateā€ˆforā€ˆ
ErPā€ˆcompliance)
ā€¢ā€ˆ Buildingā€ˆheatā€ˆloadā€ˆ(calledā€ˆPdesign)
Hitachi,ā€ˆinā€ˆcomplianceā€ˆwithā€ˆtheā€ˆEcoā€ˆDesignā€ˆDirective,ā€ˆhasā€ˆdevelopedā€ˆtheā€ˆnewā€ˆoutdoorā€ˆunits:ā€ˆnewā€ˆUTOPIAā€ˆseries,ā€ˆwhoseā€ˆ
highā€ˆefciencyā€ˆlevelā€ˆ(includingā€ˆSEERā€ˆandā€ˆSCOPā€ˆvalues)ā€ˆisā€ˆproperlyā€ˆinformedā€ˆtoā€ˆourā€ˆcustomersā€ˆtoā€ˆallowā€ˆforā€ˆanā€ˆeasyā€ˆ
selection.
Newā€ˆUTOPIAā€ˆseriesā€ˆofferā€ˆhighā€ˆseasonalā€ˆefciencies,ā€ˆasā€ˆwellā€ˆasā€ˆcompleteā€ˆī›€exibility,ā€ˆwithā€ˆallā€ˆoutdoorā€ˆunitsā€ˆfromā€ˆbothā€ˆrangesā€ˆ
beingā€ˆfullyā€ˆcompatibleā€ˆwithā€ˆtheā€ˆSystemā€ˆFreeā€ˆrangeā€ˆofā€ˆindoorā€ˆunits.ā€ˆHitachi’sā€ˆUTOPIAā€ˆtechnologyā€ˆhasā€ˆallā€ˆtheā€ˆbenetsā€ˆofā€ˆ
VRF,ā€ˆincludingā€ˆindividualā€ˆcontrolā€ˆofā€ˆeachā€ˆindoorā€ˆunitā€ˆwithā€ˆanā€ˆincreasedā€ˆnumberā€ˆofā€ˆindoorā€ˆunitā€ˆcombinationsā€ˆinā€ˆadditionā€ˆtoā€ˆ
deliveringā€ˆexcellentā€ˆpart-loadā€ˆefciency.
Withā€ˆcoolingā€ˆcapacitiesā€ˆandā€ˆheatingā€ˆcapacitiesā€ˆfromā€ˆ2HPā€ˆtoā€ˆ12HP,ā€ˆaā€ˆmaximumā€ˆofā€ˆ4ā€ˆindoorā€ˆunitsā€ˆareā€ˆconnectableā€ˆ
toā€ˆaā€ˆsingleā€ˆoutdoorā€ˆunit,ā€ˆwithā€ˆindividualā€ˆcontrolā€ˆandā€ˆefcienciesā€ˆachievedā€ˆasā€ˆhighā€ˆasā€ˆA++/A+ā€ˆ(dependingā€ˆonā€ˆmodel/
combinations).
2.2.3 Energy classes and energy label (Lot 10)
Theā€ˆenergy efciencyā€ˆclassesā€ˆfromā€ˆA+++ā€ˆtoā€ˆDā€ˆareā€ˆintroducedā€ˆbasedā€ˆonā€ˆSCOPā€ˆandā€ˆSEERā€ˆvalues:ā€ˆTheā€ˆscaleā€ˆforā€ˆenergyā€ˆ
labellingā€ˆis:
A+++
A++
D
C
B
A
A+
E
F
G SCOP < 1,90
1,90SCOP< 2,20≤
2,20SCOP< 2,50≤
2,50SCOP< 2,80≤
2,80SCOP< 3,10≤
3,10SCOP< 3,40≤
3,40SCOP< 4,00≤
4,00SCOP< 4,60≤
4,60SCOP< 5,10≤
SCOP 5,10≄
5,60SEER < 6,10≤
6,10SEER < 8,50≤
SEER 8,50≄
5,10SEER < 5,60≤
4,60SEER < 5,10≤
4,10SEER < 4,60≤
3,60SEER < 4,10≤
3,10SEER < 3,60≤
2,60SEER < 3,10≤
SEER < 2,60
Theā€ˆEnergy labelā€ˆisā€ˆtheā€ˆregulationā€ˆcompliantā€ˆwayā€ˆofā€ˆdisplayingā€ˆproductā€ˆefciencyā€ˆandā€ˆsoundā€ˆlevelā€ˆtoā€ˆanyā€ˆpointā€ˆofā€ˆsales.ā€ˆ
Thisā€ˆlabelā€ˆdisplaysā€ˆ3ā€ˆEuropeanā€ˆclimates:ā€ˆaverageā€ˆclimateā€ˆ(green),ā€ˆcoldā€ˆclimateā€ˆ(blue),ā€ˆhotā€ˆclimateā€ˆ(orange).ā€ˆRegulationā€ˆ
requirementā€ˆisā€ˆtoā€ˆdisplayā€ˆanyā€ˆinformationā€ˆrelatedā€ˆtoā€ˆperformancesā€ˆonā€ˆaverageā€ˆclimate.
Climate used on ErP Temperature used for product selection
Average -10°C
Cold -22°C
Hot +2