EasyManua.ls Logo

Hitachi RAS-8FXG User Manual

Hitachi RAS-8FXG
384 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Models
<Indoor Units>
In-the-Ceiling Type
RPI-0.8FSG1 RPI-2.5FSG1 RPI-8FSG1
RPI-1.0FSG1 RPI-3.0FSG1 RPI-10FSG1
RPI-1.5FSG1 RPI-4.0FSG1
RPI-2.0FSG1 RPI-5.0FSG1
4-Way Cassette Type
RCI-1.0FSG2 RCI-2.5FSG2 RCI-5.0FSG2
RCI-1.5FSG2 RCI-3.0FSG2
RCI-2.0FSG2 RCI-4.0FSG2
2-Way Cassette Type
RCD-1.0FSG1 RCD-2.5FSG1 RCD-5.0FSG1
RCD-1.5FSG1 RCD-3.0FSG1
RCD-2.0FSG1 RCD-4.0FSG1
•Wall Type
RPK-1.0FSGM6 RPK-2.0FSGM6
RPK-1.5FSGM6 RPK-2.3FSGM6
Floor Type
RPF-1.0FSG(E) RPF-1.5FSG(E)
Floor Concealed Type
RPFI-1.0FSG(E) RPFI-1.5FSG(E)
Ceiling Type
RPC-2.0FSG1 RPC-3.0FSG1 RPC-5.0FSG1
RPC-2.5FSG1 RPC-4.0FSG1
<Outdoor Units>
FSG(1) Series
RAS-5FSG RAS-16FSG RAS-24FSG1
RAS-8FSG RAS-20FSG RAS-30FSG1
RAS-10FSG
•FS3, FS5 Series
RAS-5FS3 RAS-16FS3 RAS-24FS5
RAS-8FS3 RAS-20FS3 RAS-30FS5
RAS-10FS3
FXG Series
RAS-8FXG RAS-10FXG
FX3 Series
RAS-8FX3 RAS-10FX3
<System Equipment>
•Total Heat Exchangers
KPI-2521 KPI-5021 KPI-8021 KPI-10021
This service mamual provides the technical
information for the HITACHI Inverter-Driven
Multi-Split System Heat Pump Air
Conditioners, “SET FREE, FSG(1)/FS3, FS5
and FXG/FX3 Series”.
Read this manual carefully before starting
service activities.
HITACHI INVERTER-DRIVEN
MULTI-SPLIT SYSTEM
HEAT PUMP AIR CONDITIONERS
SET FREE FSG(1)/FS3, FS5 SERIES
AND
SET FREE FXG/FX3 SERIES
P5413553

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAS-8FXG and is the answer not in the manual?

Hitachi RAS-8FXG Specifications

General IconGeneral
BrandHitachi
ModelRAS-8FXG
CategoryAir Conditioner
LanguageEnglish

Summary

Troubleshooting

Initial Troubleshooting

Basic checks and initial steps for unit operation issues, including switch settings.

Troubleshooting Procedure

Step-by-step guide for diagnosing issues using alarm codes and check modes.

Function of RSW, DSWs and LEDs

Explanation of rotary switches, DIP switches, and LED functions on indoor unit PCBs.

Procedure of Checking Each Main Parts

Methods for self-checking PCBs using the remote control and other components.

Self-Checking of Remote Control Switch

Procedures for checking the remote control switch's LCD and transmission circuit.

Self-Checking of Indoor Unit PCB

Steps for self-checking indoor unit PCBs using relays and check modes.

Self-Checking of 7-Day Timer (PSC-3T)

Procedure for checking the 7-day timer's LCD and touch-type switch functions.

Self-Checking of Central Station (PSC-3S1)

Overview of the central station's LCD, transmission circuit, and touch switches.

Procedure of Checking Other Main Parts

Includes high voltage discharge work and checking procedures for various modules.

Test Run

Procedures for initiating and checking the system's operation via remote control or outdoor unit.

Servicing

Outdoor Unit

Detailed instructions for disassembling and servicing outdoor unit components.

In-the-Ceiling Type (RPI-0.8FSG1 to RPI-5.0FSG1)

Procedures for removing components like filters, PCBs, and fans for specific indoor units.

In-the-Ceiling Type (RPI-8FSG1 and RPI-10FSG1)

Procedures for removing components like filters, PCBs, and fans for specific indoor units.

4-Way Cassette Type

Procedures for removing filters, grilles, electrical boxes, and fan assemblies.

2-Way Cassette Type

Procedures for removing filters, electrical boxes, optional air panels, and fan motors.

Wall Type

Procedures for removing air filters, front panels, motors, thermistors, and PCBs.

Floor Type

Procedures for removing intake grilles, air filters, front covers, fan motors, and PCBs.

Floor Concealed Type

Procedures for removing air filters, front covers, fan motors, PCBs, and thermistors.

Ceiling Type

Procedures for removing filters, side covers, discharge grilles, fan motors, and PCBs.

Total Heat Exchanger

Procedures for removing electrical parts, filters, and elements. Includes cleaning instructions.

Cleaning Indoor Unit Heat Exchanger

Detailed steps for cleaning heat exchangers for various indoor unit types.

Main Parts

Inverter

Specifications, protection functions, and overload control of the inverter unit.

AC Chopper

Concept, features, specifications, and circuit diagrams of the AC Chopper.

Auto-Louver Mechanism

Operation principles and stoppage mechanisms for auto-louver in various cassette types.

Scroll Compressor

Details on reliable mechanisms, compression principles, and structure.

Thermistor

Location and characteristics of thermistors for indoor and outdoor units.

Electronic Expansion Valve

Specifications and operating principles for outdoor and indoor electronic expansion valves.

Pressure Sensor

Details on high and low pressure control, and output characteristics.

High Pressure Protection Device

Explanation of the device and its role in controlling high pressure during heating.

Noise Filter (NF)

Specifications and circuit diagram for the noise filter.

Capacitor (CB1, CB2)

Description of the capacitor's function in inverters.

Reactor (DCL)

Description of the reactor's function in inverters.

Optional Function

Indoor Unit

Details on optional functions for various indoor unit types, including remote control settings.

Indoor Unit (For RPI (0.8 to 5.0HP), RCI, RCD, RPC (After Alteration) and KPI Series)

Input/output settings, unit selection, and optional function configuration for specific indoor units.

Outdoor Unit

Explanation of input/output terminals and function selection procedures for outdoor units.

Remote Control Switch, PC-P1H and PC-2H2

Overview of remote control switch parts and wiring for simultaneous operation.

Wireless Remote Control Switch, PC-LH3

Identification of units and optional function settings for wireless remote controls.

7-Day Timer, PSC-5T

Explanation of the timer's display and operation switch functions.

Central Station, PSC-5S

Overview of the central station's display, operation switches, and notes.

Field Work Instruction

Burnt-out Compressor due to Insufficient Refrigerant Charge

Examines compressor burnout caused by insufficient refrigerant charge and its countermeasures.

Insufficient Cooling Performance When A Long Piping Is Applied

Addresses cooling issues due to long piping and improper dip switch settings.

Abnormally High Operating Sound [In-the-Ceiling Type Indoor Unit]

Analyzes high operating sound in ceiling units due to installation without ducts and improper airflow.

Alarm Code “31”

Discusses an alarm code indicating system stoppage due to incorrect indoor/outdoor unit combinations.

Not Cooling Well due to Insufficient Installation Space for Outdoor Unit

Explains cooling issues caused by poor outdoor unit installation leading to hot air circulation.

Attention for SET-FREE FXG/FX3 Series

Provides guidance on installation sites, piping work, and simultaneous operation for FXG/FX3 series.

Select Guide of Drain Pipe for Indoor Unit

Offers guidance on selecting appropriate drain pipe diameters based on flow volume calculations.

Caution on Refrigerant Leakage

Details maximum permissible refrigerant concentration and countermeasures for leakage.

Maintenance Work

Covers routine maintenance checks for indoor and outdoor units, including fans, heat exchangers, and electrical components.

Service & Maintenance Record by 7-Segment Display

Provides a data sheet for recording service and maintenance information obtained via the 7-segment display.

Service & Maintenance Record by Remote Control Switch

Provides a data sheet for recording service and maintenance information obtained via the remote control switch.

Service & Maintenance Record

A general record for service and maintenance activities.

Related product manuals