UNITS INSTALLATION
2.1. UNIT INSTALLATION
2.1.1. FACTORY-SUPPLIED ACCESSORIES
Accessory Qty Purpose
Mounting
Bracket
1
For Mounting Indoor Unit
Screw
(Ø4×25mm)
6
Screw
(Ø4×40mm)
2
For Mounting Bracket
Plate
1
For Drain Hose Setting
Insulation Pipe
1
For Pipe
Harness With
Connector
1
Cable for servicing
2.1.2. INITIAL CHECK
Install the indoor unit with a proper clearance around it
for operation and maintenance working space as shown
below.
Consider the air distribution from the indoor unit to the
space of the room, and select a suitable location so that
uniform air temperature in the room can be obtained.
2.1.3. INSTALLATION
1. Mounting Bracket onto Wall
When the mounting bracket is directly attached to a
wood wall or a concrete wall, check to ensure that the
wall is strong enough to support a weight of 200kg.
2. Mounting the Unit between Pillars
Screws for wood market with
*
should be tightened
utilizing the upper hole.
Do not install the mounting bracket on one pillar.
The location where the indoor unit is to be installed
should be so selected that an unbalanced weight
distribution is avoided.
The mounting bracket should be installed so that the
side of drain piping connected is slightly (about 3mm)
lower than the other side, in order to avoid the incorrect
position of the drain discharge. (Drain piping connection
can be performed both right side and left side of the
unit.)
3. Mounting on a Concrete Wall or a Concrete Block Wall
Attach the mounting bracket to the wall with anchor bolts
as shown below.
Utilize at least 4 anchor bolts (M4-M5).
4. Mounting the Indoor Units
Hook the indoor unit to the mounting bracket,
maintaining the indoor unit upright. Fix the bottom cover
to the mounting bracket.
5. Check to ensure that the unit is completely hooked onto
the mounting bracket. If not, it may drop from the
bracket, resulting in a serious accident.
Screw
Plug
Mounting
Bracket
Indoor
Unit
Outdoor
Unit
(mm)
2~5 mm
Diameter
of 65 mm
(Hole for
piping)
(Operation and Installation Space)
(Hole for Piping on the wall)
Wall
Mounting
Bracket
Screws for
Mounting Bracket
Utilize at least
4 screws
Piping
Connections
Hook
Mounting
Bracket
Extrusion
Hook
*
*