What to do if Hitachi YUTAKI M RASM-6NE Air Conditioner has Receiver Communication failure?
- VvscottAug 31, 2025
If your Hitachi Air Conditioner is not receiving a signal, check the Opentherm/Hlink connection.

What to do if Hitachi YUTAKI M RASM-6NE Air Conditioner has Receiver Communication failure?
If your Hitachi Air Conditioner is not receiving a signal, check the Opentherm/Hlink connection.
What to do if Hitachi YUTAKI M RASM-6NE Air Conditioner shows abnormal transmission between outdoor and indoor units?
If your Hitachi Air Conditioner shows 'Abnormal transmission between outdoor and indoor units', check the wiring, terminals, and PCB for faults. This issue can be caused by incorrect wiring, loose terminals, PCB failure, a tripped fuse, or the power supply being OFF.
Why does my Hitachi Air Conditioner activate safety device from excessively high discharge pressure?
If your Hitachi Air Conditioner activates the safety device due to excessively high discharge pressure, inspect the heat exchanger and refrigerant conditions. This activation can be caused by overload (obstruction of HEX, short circuit), a mixture of inert gas, or excessive refrigerant.
What causes Hitachi Air Conditioner to activate safety device from excessively low suction pressure?
If your Hitachi Air Conditioner activates the safety device from excessively low suction pressure, inspect refrigerant levels and piping for blockages. This issue is often due to a shortage or leakage of refrigerant, piping clogging, a closed expansion valve, or a locked fan motor.
How to troubleshoot Hitachi YUTAKI M RASM-6NE Air Conditioner hydraulic alarm flow and water pump malfunction?
If your Hitachi Air Conditioner displays a hydraulic alarm related to flow and water pump malfunction, check the water pump for proper operation and repair or replace it if defective. This alarm indicates that water flow is not detected in the hydraulic cycle or the pump is defective.
What to do if Hitachi Air Conditioner shows Thermostat Heater Alarm?
If your Hitachi Air Conditioner is showing a high temperature in the electric heater, check the electric heater for proper operation.
How to fix Hitachi YUTAKI M RASM-6NE Air Conditioner activation of overcurrent protection?
If your Hitachi Air Conditioner activates overcurrent protection, inspect the inverter PCB and compressor operation. This can be caused by overload, overcurrent, failure of the Inverter PCB, a clogged heat exchanger, a locked compressor, or EVI/EVO failure.
How do I fix a 'Unit Capacity setting Error' on my Hitachi Air Conditioner?
If your Hitachi Air Conditioner displays a 'Unit Capacity setting Error', ensure correct capacity settings for both indoor and outdoor units. This error indicates a mismatch between the indoor and outdoor unit capacities.
How to correct Hitachi Air Conditioner incorrect indoor unit number setting?
If your Hitachi Air Conditioner displays 'Incorrect indoor unit number setting', correct the indoor unit number settings. This issue can be caused by duplication of indoor unit numbers or the number of indoor units exceeding specifications.
How to fix Incorrect PCB Setting in Hitachi YUTAKI M RASM-6NE?
If your Hitachi Air Conditioner shows 'Incorrect PCB Setting', correct the DSW settings. This issue is caused by a wrong DSW setting in the case of Co041.
| Model | RASM-6NE |
|---|---|
| Cooling Capacity | 6.0 kW |
| Seasonal Energy Efficiency Ratio (SEER) | 6.1 |
| Refrigerant | R410A |
| Heating Capacity | 7.0 kW |
| Type | Split System Air Conditioner |
Describes the classification of split and monobloc units based on model codes.
Provides detailed DANGER and CAUTION information for safe operation.
Important instructions regarding manual reading, specifications, and usage.
Provides nominal capacity and performance data for YUTAKI S units.
Details Energy-related Product (ERP) performance data for space heaters.
Specific ERP data for YUTAKI S space heaters under average climate conditions.
Specific ERP data for YUTAKI S COMBI units under average climate conditions.
Illustrates temperature working ranges for space heating and DHW.
Shows temperature ranges for space heating for YUTAKI M and S80.
Shows temperature ranges for DHW for YUTAKI (S/S COMBI), M, and S80.
Illustrates refrigerant and hydraulic circuits for split systems.
Illustrates refrigerant and hydraulic circuits for the monobloc YUTAKI M system.
Critical safety precautions for refrigerant leakage scenarios.
Details on power supply requirements and wiring.
Specifies wire sizes for power supply and communication cables.
Minimum requirements for Earth Leakage Breakers (ELB) and Circuit Breakers (CB).
Provides a step-by-step guide for configuring the system.
Lists indoor unit alarms, their codes, details, and main factors.
Lists outdoor unit alarms, their codes, details, and main factors.
Lists alarms indicated on the LCD screen.
General guidelines for maintenance tasks.
Detailed maintenance steps for the outdoor unit components.
Detailed maintenance steps for indoor unit components.