S
Samuel HamptonAug 31, 2025
What to do if Hitachi YUTAKI S COMBI RWD-4.0NWE-200S has Receiver Communication failure?
- SSean DavisAug 31, 2025
If your Hitachi Air Conditioner is not receiving a signal, check the Opentherm/Hlink connection.
What to do if Hitachi YUTAKI S COMBI RWD-4.0NWE-200S has Receiver Communication failure?
If your Hitachi Air Conditioner is not receiving a signal, check the Opentherm/Hlink connection.
How to fix Incorrect PCB Setting in Hitachi YUTAKI S COMBI RWD-4.0NWE-200S Air Conditioner?
If your Hitachi Air Conditioner shows 'Incorrect PCB Setting', correct the DSW settings. This issue is caused by a wrong DSW setting in the case of Co041.
How to correct Hitachi Air Conditioner incorrect indoor unit number setting?
If your Hitachi Air Conditioner displays 'Incorrect indoor unit number setting', correct the indoor unit number settings. This issue can be caused by duplication of indoor unit numbers or the number of indoor units exceeding specifications.
How do I fix a 'Unit Capacity setting Error' on my Hitachi YUTAKI S COMBI RWD-4.0NWE-200S Air Conditioner?
If your Hitachi Air Conditioner displays a 'Unit Capacity setting Error', ensure correct capacity settings for both indoor and outdoor units. This error indicates a mismatch between the indoor and outdoor unit capacities.
How to fix Hitachi YUTAKI S COMBI RWD-4.0NWE-200S activation of overcurrent protection?
If your Hitachi Air Conditioner activates overcurrent protection, inspect the inverter PCB and compressor operation. This can be caused by overload, overcurrent, failure of the Inverter PCB, a clogged heat exchanger, a locked compressor, or EVI/EVO failure.
What to do if Hitachi Air Conditioner shows Thermostat Heater Alarm?
If your Hitachi Air Conditioner is showing a high temperature in the electric heater, check the electric heater for proper operation.
How to troubleshoot Hitachi Air Conditioner hydraulic alarm flow and water pump malfunction?
If your Hitachi Air Conditioner displays a hydraulic alarm related to flow and water pump malfunction, check the water pump for proper operation and repair or replace it if defective. This alarm indicates that water flow is not detected in the hydraulic cycle or the pump is defective.
What causes Hitachi YUTAKI S COMBI RWD-4.0NWE-200S to activate safety device from excessively low suction pressure?
If your Hitachi Air Conditioner activates the safety device from excessively low suction pressure, inspect refrigerant levels and piping for blockages. This issue is often due to a shortage or leakage of refrigerant, piping clogging, a closed expansion valve, or a locked fan motor.
Why does my Hitachi Air Conditioner activate safety device from excessively high discharge pressure?
If your Hitachi Air Conditioner activates the safety device due to excessively high discharge pressure, inspect the heat exchanger and refrigerant conditions. This activation can be caused by overload (obstruction of HEX, short circuit), a mixture of inert gas, or excessive refrigerant.
What to do if Hitachi Air Conditioner shows abnormal transmission between outdoor and indoor units?
If your Hitachi Air Conditioner shows 'Abnormal transmission between outdoor and indoor units', check the wiring, terminals, and PCB for faults. This issue can be caused by incorrect wiring, loose terminals, PCB failure, a tripped fuse, or the power supply being OFF.
Type | Air-to-water heat pump |
---|---|
Heating Capacity | 4.0 kW |
Cooling Capacity | 4.0 kW |
Energy Efficiency Class | A++ |
Refrigerant | R32 |
Energy Efficiency Ratio (Heating) | 4.5 |
Power Supply | 230V, 50Hz |
Provides critical DANGER and CAUTION statements regarding electrical safety, component handling, and operational hazards.
Details power supply specifications, and temperature ranges for space heating, DHW, swimming pool, and cooling.
Ensures proper power supply, installation checks, wiring size, and protection device requirements.
Guides through initial system setup with a wizard and advanced configuration for system parameters.
Lists common alarm codes for indoor units, their details, and main contributing factors for troubleshooting.
Details various types of abnormalities for outdoor units, including their code, category, type, and main causes.