8.6.4.3 Screed Drying
REF Access Description
Default
Value
Range Steps Units Application
Notes
Screed Drying S SC S80 M
SDC1
Circuit 1 Setting T 55 Limits installer 1 ºC (*1)
SDC2
Circuit 2 Setting T 55 Limits installer 1 ºC (*2)
- Start Screed Drying - - - -
? NOTE
(*1): If Water calculation mode for circuit 1 heating (C1WC) or Water calculation mode for circuit 1 cooling (CC1WC) are not set as “Disabled”.
(*2): If Water calculation mode for circuit 2 heating (C2WC) or Water calculation mode for circuit 2 cooling (CC2WC) are not set as “Disabled”.
8.6.5 About
In this menu, it is possible to consult some useful information. There are two main options:
System Information
Contact Information
8.6.5.1 System Information
System information view will give the version number of the Yutaki and the PC-ARFHE. It will be done in a view as the following one:
In this view, nothing can be edited.
It will appear:
Unit Type (S/SC/S80/M)
Unit Capacity
Controller Firmware: is the H-0XX software name of the LCD
Indoor PCB Firmware: ROM Number is a variable read from H-LINK, it is the 11-302
variable and transformed to H-00XX
Language Package: group of available languages
8.6.5.2 Contact Information
In the contact information, it can be entered:
Name: every character could be entered from HAPE Ascii character map
Phone Number: every number can be from 0 to 9 and “-“
These variables are only editable in the installer mode.
After changing a letter a broadcast message is set at informing to all the slave devices the new text to have all of them synchronized.
UNIT CONTROLLER
PMML0335A rev.1 - 04/2016
166