ENGLISH
Circuit 2
REF Access Description
Default
Value
Range Steps Units Application
Notes
Circuit 2 S SC S80 M
-
Heating (Air)
- - - -
(*1)
- Cooling (Air) - - - - x (*2)
-
Heating (Water)
- - - -
(*3)
-
Cooling (Water)
- - - -
x (*4)
? NOTE
(*1): If Controller type (LCDM)= “Unit” or “Unit + Room” and Controlled circuits (LCDL)=“Room C2” or “C1+C2”.
(*2):If cooling operation is enabled and if Controller type (LCDM)= “Room” or “Unit + Room” and Controlled circuits (LCDL)=“Room C2” or “C1+C2”.
(*3):If Controller type (LCDM)= “Unit” or “Unit + Room” and Water calculation mode for circuit 2 heating (C2WC) is not “Disabled”.
(*4): If cooling operation is enabled and if Controller type (LCDM)= “Unit” or “Unit + Room” and Water calculation mode for circuit 2 cooling
(CC2WC) is not “Disabled”.
Timer and Schedule ‘any of the previous views’
Each of the following submenus share these parameters shown on the table
Circuit 1 Heating (Air)
Circuit 1 Cooling (Air)
Circuit 1 Heating (Water)
Circuit 1 Cooling (Water)
Circuit 2 Heating (Air)
Circuit 2 Cooling (Air)
Circuit 2 Heating (Water)
Circuit 2 Cooling (Water)
DHW
SWP
REF Access Description
Default
Value
Range Steps Units Application
Notes
Common S SC S80 M
- Timer Type Disabled
Disabled
Simple
Schedule
- Timer conguration (*) - - - - (*1)
-
Copy to Circuit 2 (*) - - - - (*2)
- Copy to Circuit 1 (*) - - - - (*3)
- Frequency (*)
Never
Once
Everyday
Weekend
Workday
- - (*4)
- Starting time 06:00
00:00 to Stopping –
00:10
ºC 00:10 (*4)
- Mode Eco
Eco
Comfort
Setting Temperature
- - (*4)
- Setting Temperature (*) (*) ºC 1 (*5)
- Stopping time 12:00 Starting +00:10 to 24:00 - 00:10 (*4)
- Conguration Parameters - - - - (*6)
- Change Mode - - - - (*1)
- Reset conguration - - - - (*1)
? NOTE
(*1): If timer type= “Schedule”.
(*2): If time type= “Schedule” and if the selected timer is “Circuit 1” (Air/Water) and if exist 2 circuits in the same controller and the timer mode is
the same between them.
UNIT CONTROLLER
PMML0335A rev.1 - 04/2016
141