3.2 The input power (Power IN 12V/24VDC) is connected to the input connector of LAKC1-1.
3.3 When the input power is connected (connecting as a figure below), the inner tube of actuator will extend
outward.
3.4 When the input power is reversely connected (wiring as a figure below), the inner tube of actuator will draw
inward.
3.5 When an actuator encounters an unknown obstacle during the operation or the overload time exceeds 0.8
seconds, LAKC1-1 will automatically stop.
3.6 After activating LAKC1-1, it means the working current has exceeded the rating. At this time, you must
disconnect the input power to reset LAKC1-1.
4. Notice:
4.1 Please read a label of power supply indicated on over current protector before using this product, and
ensure the supplied power can obey this product requirement.
4.2 Turn on the power after LAKC1-1 over current protectors and actuators are installed.
4.3 If users select over current protector below 10A according to the product specifications, we recommend an
input and output power cord within 5m with 1.25mm2 wire. If users select over current protector above 10A,
we recommend input and output power cord within 5m with 2mm2 wire to reduce over current caused by large
resistance in a power cord.
4.4 If users select the length of input and output power wire over 5m, we recommend a larger diameter of power
cord (greater than 2mm²) be selected to reduce over current caused by large resistance.