5. Caution Notice:
1. Carefully read power supply indicated on the specification label of a control box before using this product.
Moreover, confirm the supplied power complies with product requirement. If there is product damage or
personnel injury caused by wrong supplied power, we will not take responsibility
2. Turn on the power after a controller and an actuator are installed.
3. Because there is a limit of power for transformer built in a controller, please ensure if the load exceeds the
rating output power of a controller before combining with an actuator. Over rating will result in the reduction of
maximum thrust and speed for an actuator as well as the temperature increase of a controller.
4. Don’t handle this product yourself if faults occur. This product can be repaired by our qualified technicians only.
5. If the leading connector of a controller is Y type and that is damaged , please contact manufacturer or product
agency to replace it to avoid dangerous.
6. LAKC Over Current Protection Box
1. Specification and Operation Environment:
1.1 Suitable for LAS1~LAS4,LAM1,LAN1~LAN5 series.
1.2 LAKC1-1 is an over current protector for uniaxial linear actuator, which can avoid over current caused by
actuator overload or other abnormal situations.
1.3 Power supply: 12VDC or 24VDC; the required input power is indicated on a label of specification.
1.4 The value of over current is indicated on the specification label.
1.5 Duty cycle: 10%
1.6 Protection class: IP54 (upgrade to IP66 by demand)
1.7 Operation and environment temperature: +5℃~40℃ (41°F~104°F)
2. LAKC1-1 Installation Guide:
Fix two screw holes when installing, and avoid the fall of power wire by shaking an over current protector.
3. Operation Guide:
3.1 The installation of LAKC1-1 is shown in a figure below. An actuator for LAKC1-1 is connected to an output
connector of LAKC1-1.