EasyManua.ls Logo

Holmatro DPU31 - Fuel and Fluid Handling; Gasoline Safety and Type; Hydraulic Oil Safety and Type; Engine Starting Procedure

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Gasoline:
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
* Check the fuel level. Fill to recommended level if low.
* Use only un-leaded gasoline.
* Do not overfill the tank.
* Immediately remove any gasoline that spills.
Hydraulic oil:
Use only Holmatro recommended hydraulic
fluid. Use of hydraulic fluid other than that
recommended may cause damage to the pump.
* Check the hydraulic oil level through the level indicator on the front cover
* Fill to recommended level, shown on indicator decal, if low.
* Use only Holmatro recommended hydraulic oil.
* Do not overfill the tank.
* Immediately remove any hydraulic oil that spills.
9.2.2 Starting:
First complete the checklist in section 9.2.1.
* Turn the fuel cap vent lever to the ON position.
* Switch the choke lever to its CHOKE position.
* Turn engine switch to the ON or “1”position.
* Pull the cord until resistance is felt, let the cord be retracted and then pull fast. Repeat
this if the engine does not start the first time.
* Guide the starting cord back after starting.
Switch the choke lever to RUN when the engine has warmed up after approx. 20 - 30 seconds, or
when the engine begins to run irregularly.
NOTE: Start in the RUN position if the engine is still warm. Start in the CHOKE position if the
engine is cold or runs out of gasoline during operation.
NOTE: During equipment testing operations, run the engine for at least 20 minutes or until the
engine reaches operating temperature. (Depending on ambient temperature. Run the
engine longer in colder weather)