B. Drive 3/4” or 1/2” locking screws through frame
holes into window sash (Fig.8).
C. To secure lower sash in place, attach right angle
sash lock with 3/4” or 1/2” screw as shown (Fig.9).
D. Cut Window sash seal foam and insert it in the
space between the upper and lower sashes (Fig.10).
INSTALLATION INSTRUCTIONS
IF A/C IS BLOCKED BY STORM WINDOW
Add wood as shown in Fig. 11, or remove storm
window before air conditioner is installed.
If Storm Window Frame must remain, be sure the
drain holes or slots are not caulked or painted shut.
Accumulated Rain Water or Condensation must be
allowed to drain out.
• Turn AC off, and disconnect power cord.
• Remove sash seal from between windows,
and unscrew safety sash lock.
• Remove screws installed through frame and
frame-lock.
• Close (slide) side panels into frame.
• Keeping a rm grip on air conditioner, raise
sash and carefully remove.
• Be carefully not to spill any remaining water
while lifting unit from window. Store parts
WITH air conditioner.
Fig. 8
Fig. 9
Fig. 10
Fig. 11
FOAM SEAL
SASH
1-1/2” min
(38mm)
Storm window
frame or other
obstruction.
Board thickness
as required, for
proper pitch to
rear, along entire
sill. Fasten with
nails or screws.
Removing AC From Window