PRO 2000 SERIES
5 69-1969EFS—09
IN CASE OF DIFFICULTY
Table 2.
CUSTOMER ASSISTANCE
Fig. 9.
Screen is blank. Check circuit breaker and reset if necessary.
Ensure the heating/cooling system is powered up.
Ensure the furnace door is properly closed.
Ensure two fresh AAA alkaline batteries are correctly installed.
Temperature settings cannot be
changed.
•The System switch is off.
You are setting the temperature outside its allowable range:
Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
Cool: 50 °F to 99 °F (10 °C to 37 °C).
Cool On or Heat On is flashing. The compressor protection delay is underway. Wait for the delay to end
(maximum of 5 minutes).
HI appears on the screen. The ambient (measured) temperature is above 122 °F (50 °C).
LO appears on the screen. The ambient (measured) temperature is below 32 °F (0 °C).
E1 appears on the screen. The temperature sensor circuit is opened. Replace the thermostat.
E2 appears on the screen. The temperature sensor circuit is shorted. Replace the thermostat.
For assistance with this product, please visit
www.resideo.com.
Or call Resideo Customer Care toll-free at
1-800-468-1502.
To save time, please note your model number
and date code before calling.