GENERAL INFORMATION
The ADEMCO 6460S (silver) and 6460W (white) are
addressable Remote Keypads designed for use with
Honeywell's ADEMCO series control panels. Addresses are
set via the keypad keys.
The keys on the keypad are continuously backlit for
convenience.
NOTE: If supported, the ADEMCO 6460S and 6460W
keypads are supervised by control panel. Supervision must
be enabled for commercial fire installations.
KEYPAD DISPLAYS AND LEDS
The ADEMCO 6460S and 6460W keypads have the
following display features:
2-line Alpha Display
Custom Zone Descriptors
Built-in Speaker Sounder
Dedicated Function Keys
Backlit Display (permanent display backlighting is
an option on some controls; see the control's
instructions for details).
The following table shows the LEDs and their functions:
LED Function
Red Lights when the system is armed in any mode
Green Lights when the system is "ready" to be armed.
SPECIAL FUNCTION KEYS
The keypads also feature function keys. These keys may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.
Function keys must be held down for at least 2
seconds to activate an alarm; key pairs are activated
immediately.
Function Keys
A or [1] and []
B or [] and [#]
C or [3] and [#]
D
WIRING AND INSTALLATION
The keypads can be surface mounted directly to a drywall,
or to a single- or double-gang electrical box.
1. Push the two case release snaps at the bottom of the
keypad with the blade of a medium screwdriver (this will
push in the release snap), then pull that side of the case
back away. Refer to Figure 1 for location of the case back
release snaps.
2. Route wiring from the control panel through the opening
in the case back.
3. Mount the case back to a wall or electrical box.
4. Wire directly from the keypad’s terminal block to the
terminal block on the control panel. (See Wiring Table
below).
NOTE: No more than one wire per terminal may be
connected. If daisy-chained configuration is required,
pig-tail wires together so that only one wire is
terminated under the screw. Use 16-24 AWG wire only!
Wiring Table
Keypad Control Panel Wire Color
G
Data In Green
– Aux Pwr (GND) Black
+ + Aux. Pwr Red
Y
Data Out Yellow
See the control panel’s Installation and Setup Guide for
more complete details.
5. Reattach the keypad to its case back.
JKL
AWAY
CODE
ARMED
READY
S
T
A
Y
O
F
F
M
A
X
D
I
N
S
E
N
I
G
H
R
S
P
Q
T
T
A
N
R
E
A
D
Y
B
Y
P
A
S
S
C
H
I
M
E
TEST
4
6
TUV
9
0
N
O
M
X
Z
Y
W
U
M
N
E
F
D
ABC
3
5
8
2
1
7
*
#
NOTE:
TO REMOVE CASE BACK
PUSH IN THE TWO RELEASE
SNAPS LOCATED ALONG THE
BOTTOM OF THE KEYPAD
AND LIFT UP.
6460S-001-V1
RELEASE
SNAPS
DCBA
Figure 1. Removing the Case Back
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Question and Answer IconNeed help?

Do you have a question about the Honeywell Ademco 6460S and is the answer not in the manual?

Honeywell Ademco 6460S Specifications

Display IconDisplay
display type2 x 16 alpha-numeric supertwist LCD
display featurebacklit
Power IconPower
voltage12VDC
current in alarm mode150mA
current in standby mode40mA
Weight and Dimensions IconWeight and Dimensions
height5-9/16"
width6-3/4"
depth1"

Summary

General Information

Keypad Displays and LEDs

Keypad Display Features

Describes the 2-line Alpha Display, Custom Zone Descriptors, Built-in Speaker, and Dedicated Function Keys.

Keypad LED Functions

Details the function of Red and Green LEDs on the keypad for system status.

Special Function Keys

Special Function Key Operation

Explains how to activate special function keys, requiring a 2-second hold for alarms.

Wiring and Installation

Wiring and Installation Steps

Details the process of mounting, wiring, and connecting the keypad to the control panel.

Setting the Keypad Address

Keypad Address Configuration

Step-by-step guide to set the keypad's address from 00-30 or non-addressable mode (31).

Viewing Keypad Address

Procedure to display the currently set address of the keypad.

Function Key Labels

Function Key Labeling

Information on provided adhesive labels for customizing function key identification.

Operating the Keypad

Keypad Operation Guide

Refers to the control panel User Guide for detailed instructions on keypad operation.

Specifications

Physical Specifications

Dimensions of the keypad: 5-9/16"H x 6-3/4"W x 1"D.

Display Specifications

Details the 2 x 16 alpha-numeric supertwist LCD, backlit display.

Sounder Specifications

Specifies the keypad includes a built-in speaker.

Voltage Specifications

The keypad requires 12VDC (power-limited).

Current Consumption

Details current draw in alarm (150mA) and standby (40mA) modes.

NFPA-72 Compliance

Indicates compliance with NFPA-72 standards.

Related product manuals