– 15 –
OUTPUT RELAYS WORKSHEETS FOR ∗
∗∗
∗79, ∗
∗∗
∗80 and ∗
∗∗
∗81 (Applicable only if Relays are to be used)
∗
∗∗
∗79 RELAY MAPPING WORKSHEET
(Must program before using *80)
Output No. Module Addr. Pos (1-4) Description
01
12
02
12
03
12
04
12
17
On-Board Trigger 1: Norm output =
18
On-Board Trigger 2: Norm output =
∗
∗∗
∗80 OUTPUT DEFINITIONS WORKSHEET
Activation Type and Detail Event (for zone list/activated by)Output
Function
Number
1-12
Activated by
0=delete
1=zn list
2=zn type
3=zn no.
Zone List
(ZL)
1-8 = list
Zone Type
(ZT)
(see table
below)
Zone No.
(ZN)
00=none
01-06,
09-24
49-56
By Zone List
0 = restore
1 = alarm
2 = fault
3 = trouble
By Zone No.
0 = restore
1 = alrm/flt/trbl
Action
0 = off
1 = close 2 secs
2 = stay closed
3 = pulse
4 = toggle
5 = duration 1
††
6 = duration 2
††
Output
Number
1-4
17, 18
Device
Type
R = relay
T = trigger
1
2
3
4
5
6
7
8
9
10
11
12
ZONE TYPE/SYSTEM OPERATION – Choices for Zone Types are:
00 = Not Used 05 = Trouble Day/Alarm Night 10 = Interior w/Delay 24 = Silent Burglary
01 = Entry/Exit#1 06 = 24 Hr Silent 12 = Monitor Zone 77 = Keyswitch
02 = Entry/Exit#2 07 = 24 Hr Audible 14 = Carbon Monoxide 81 = AAV Monitor Zone
03 = Perimeter 08 = 24 Hr Aux 16 = Fire w/Verification 90 = Configurable
04 = Interior Follower 09 = Fire 23 = No Alarm Response
Choices for System Operation are:
20 = Arming–Stay 38 = Chime 52 = Kissoff
21 = Arming–Away 39 = Any Fire Alarm 54 = Fire Zone Reset
22 = Disarming (Code + OFF) 40 = Bypassing 58 = Duress
31 = End of Exit Time 41 = AC Power Failure 60 = AAV Trigger
32 = Start of Entry Time 42 = System Battery Low 66 = Function key†
33 = Any Burglary Alarm 43 = Communication Failure 67 = Bell Failure
36 = **At Bell Timeout*** 68 = Telco Line Fault
78 = Keyswitch Red LED†††
79 = Keyswitch Green LED†††
∗
∗∗
∗81 ZONE LISTS WORKSHEET
Record desired zone numbers below, noting that a list may include
any
or
all
of system's zone numbers.
List No. Used For… Contains These Zones…
01 General Purpose (GP)
02 General Purpose
03 Chime-by-Zone or GP
04 Cross Zones
05 Night-Stay Zones or GP
06 Dial Delay Disable or GP VISTA-10PSIA: see field *50 for Dial Delay Disable option
07 Unlimited Reports or GP VISTA-10PSIA: see field *93 for Unlimited Reports option
08 General Purpose
09 Zones activating pager
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device
Code + # + 8 + NN Key Entry stops Device
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu mode to assign the function key.
†† Duration is set in program field *177.
††† Device action not used for these choices.
WWW.DIYALARMFORUM.COM