56 ZONE PROGRAMMING MENU MODE
(press *56 while in Program mode)
SET TO CONFIRM?
0 = NO 1 = YES
We recommend that you select yes to confirm the programming of every transmitter.
If selected, a prompt appears after entering the serial and loop numbers to confirm each transmitter)
Enter Zn Num.
(00 = Quit) 10
Enter the zone number being programmed:
01-06 = wired zones; 09-24 = wireless zones; 49-56 = button zones
91 = addr. device report enable (Enter a report code for zone 91 to enable addressable device reporting.
92 = duress report enable (Enter a report code for zone 92 to enable duress reporting)
95, 96, 99 =emergency zones
00 to quit; [] to continue
Zn ZT P RC In: L
10 00 1 10 RF: 1
Summary Screen for the selected zone is displayed.
IN: L = input type and loop; HW: RT = basic wired zone configuration (EOL, NO, NC) and response time
[] to continue
10 Zone Type
Perimeter 03
Enter the desired ;zone type from the list below. If 00 is entered, Delete Zone ? is displayed.
00 = Not used 07 = 24-Hr Audible 20 = ArmSTAY*
01 = Entry/exit #1 08 = 24-Hr Aux 21 = ArmAWAY*
02 = Entry/exit #2 09 = Fire 22 = Disarm*
03 = Perimeter 10 = Interior w/Delay 23 = No Alarm Resp*
04 = Interior Follower 12 = Monitor Zone 24 = Silent Burglary
05 = Trouble Day/Alarm Night 14 = Carbon Monoxide 77 = Keyswitch
06 = 24-Hr Silent 16 = Fire w/Verify 81 = AAV Monitor Zone
*5800 button-type transmitters only 90 = Configurable
10 Report Code
1st 01 2nd 00 10
Enter the report code for this zone, which consists of 2 hexadecimal digits, each in turn consisting of two
numerical digits. For example, for a report code of 10, enter 01 and 00.
For Contact ID®, entering any non-zero entry as the first digit enables the report code for this zone.
1-9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F
00 to disable;
[] to continue
02 HARDWIRE TYPE
EOL 0
This prompt appears only for zone numbers 01-06.
Enter the desired hardwire type:
0 = EOL; 1 = NC; 2 = NO
[] to continue
02 Response Time
1
This prompt appears only for hard-wired zones 01-06 (zone 02 is used as an example in display).
Enter the desired response time for this zone:
0 = 10mSec; 1 = 350mSec; 2 = 700mSec; 3 = 1.2 seconds
[] to continue
10 INPUT TYPE
RF TRANS 3
This prompt is skipped for zones 1-6.
Select the desired input type for the transmitter zone being programmed (some transmitters have more than
one input loop, each requiring its own zone; e.g., a 5804's four inputs requires four zones).
3 = RF (supervised RF transmitter; sends fault, restore, and low-battery signals, and sends periodic check-
in signals; transmitter must stay within receiver's range)
4 = UR (unsupervised RF transmitter; sends fault, restore, and low-battery signals, but does not send
periodic check-in signals; transmitter may be carried off-premises)
5 = BR (unsupervised button type RF transmitter; sends fault and low battery signals when activated, does
not send restore or check-in signals; transmitter may be carried off-premises)
[] to continue
NOTES:
For the built-in basic wired zones, the Input Device type is automatically displayed as HW and cannot be
edited.
10 INPUT S/N: L
A022-4064 1
For wireless transmitters, enroll the serial number and loop number.
1. a. Transmit two open/close sequences. If using a button-type transmitter, press and release the button
twice, but wait about 4 seconds before pressing the button the second time.
OR
b. Manually enter the 7-digit serial number printed on the label of the transmitter.
Press the [] key to move to the L position, then enter the loop number (see Loop Identification chart
on back cover).
If desired, you can press the [C] key to copy the previously enrolled serial number (used when
programming a transmitter with several input loops). The cursor moves to the loop number position.
c. To delete an existing serial number, enter 0 in the loop number field. The serial number will change to
0's. If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will
return to the display.
2. Press [] to continue. The system now checks for a duplicate serial/loop number combination.
10 INPUT S/N L
A022-4064 1
If the serial/loop number combination is not a duplicate in the system, a display showing the serial number
and loop number entry appears.
[] to continue
XMIT TO CONFIRM
PRESS TO SKIP
This prompt will only appear if you answered Yes at the SET TO CONFIRM prompt.
The system now enters a confirmation mode so that the operation of the actual programmed input can be
confirmed.
Activate the loop input or button that corresponds to this zone.
[] to continue