5-3
PROMPT
VALID ENTRIES EXPLANATION
10 INPUT S/N: L
A022-4064 1
Serial number Entry
and Loop Number Entry
see explanation
[] to continue
Used only when enrolling wireless transmitters.
a. Transmit two open/close sequences. If using a button-type
transmitter, press and release the button twice, but wait about 4
seconds before pressing the button the second time.
OR
b. Manually enter the 7-digit serial number printed on the label of
the transmitter. Then press the [] key – the cursor will move to
the “L” position. You can edit the loop number, if necessary. When
the loop number is acceptable, press [].
c. Press key [C] to copy the serial number previously enrolled (used
when programming a transmitter with several input loops).
10 INPUT S/N L
A022-4064 ?
Loop Number Change
[] to continue
NOTE: If the [C] key is used to copy the previously enrolled serial
number, the cursor will move to the Loop column (L) with the
previous serial number displayed, and display a highlighted question
mark for the loop number.
Enter the loop number and press []. The system will now check for a
duplicate serial/loop number combination.
10 INPUT S/N L
A022-4064 1
Enroll Summary
[] to continue
If the serial/loop number combination is not a duplicate in the
system, a display showing the serial number and loop number entry
will appear.
To Delete an Existing Serial Number: Enter 0 in the loop number
field. The serial number will change to 0's.
10 INPUT S/N: L
A000-0000 0
If 0 was entered in error, simply re-enter the loop number or press
[#], and the serial number will return to the display.
XMIT TO CONFIRM
PRESS TO SKIP
Confirmation Option
Activate the loop input or button
[] to continue
This prompt will only appear if you answered “Yes” at the first
prompt in this section.
The system will enter a confirmation mode so that the operation of
the actual programmed input can be confirmed.
Activate the loop input or button that corresponds to this zone.
If the serial number and/or loop number transmitted does not match
the serial number entered, a display similar to the one below appears.
Entd A022-4063 1
Rcvd A022-4064 1
If so, activate the loop input or button on the transmitter once again.
If a match is not obtained (i.e., summary display does not appear),
press the [#] key twice and then enter (or transmit) the correct serial
number.
Press [] to continue.
Zn ZT RC In: L
10 03 10 RF: 1s
Summary Screen
[] to continue
If the serial number transmitted matches the serial number
entered, the keypad will beep 3 times and a summary display
will appear, showing that zone's programming. Note that an
“s” indicates that a transmitter’s serial number has been
enrolled.
Press [] to accept the zone information and continue.
PROGRAM ALPHA?
0 = NO 1 = YES 0
Alpha Descriptors
0 = no
1 = yes
[] to continue
If you want to program descriptors for zones now, enter 1 (Yes) and
refer to the Alpha Descriptor Programming section for the
procedure to use.
ENTER ZN NUM.
(00 = QUIT) 11
Next Zone Number
00 = quit
[] to continue
If 0 (No) was entered above, the system will return you to the ENTER
ZN NUM. prompt for the next zone.
When all zones have been programmed, enter 00 to quit.