5-11
01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[∗] to continue
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to “A” prompt)
2 = zone type (go to “B” prompt)
3 = zone number (go to “C” prompt)
If you enter “0,” the following prompt appears:
Delete? Press 1 to delete this
0 = NO, 1 = YES output definition.
“A”
01 Zn List
1
Zone List
01-12 = zone list
[∗] to continue
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Zone lists 09-12 can be used in output definitions if not used
for paging or for exit zone definition.
Press [
∗
] to continue.
Enter the zone list event that will activate this output.
Enter Event 0 = restore; 1 = alarm;
Alarm 1 2 = fault; 3= trouble
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [
∗
] to continue and skip to the “Output Action” prompt.
“B”
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used 05 = Trouble Day/Alarm Night 14 = Gas
01 = Ent/Exit #1 06 = 24 Hr Silent 16 = Fire w/verification
02 = Ent/Exit #2 07 = 24 Hr Audible 23 = No Alarm Response
03 = Perimeter 08 = 24 Hr Aux 24 = Silent Burglary
04 = Interior Follower 09 = Fire 77 = Keyswitch
10 = Interior w/Delay 81 = AAV Monitor Zone
12 = Monitor Zone 82 = Blockschloss
90-93 = Configurable
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay 36 = **At Siren Timeout*** 54 = Fire Zone Reset
21 = Arming–Away 38 = Chime 58 = Duress
22 = Disarming 39 = Any Fire Alarm 60 = AAV
31 = End of Exit Time 40 = Bypassing 66 = Function Key†
32 = Start of Entry Time 41 = **AC Mains Failure 67 = Siren Fail
33 = Any Burglary Alarm 42 = **System Battery Low 68 = Telecom Line Cut
43 = Comm. Failure 78 = Keyswitch Red LED
52 = Kissoff 79 = Keyswitch Green LED
80 = Tamper Fault
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
†
Use *57 Menu Mode to assign the function key (function “07”).
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition 0 = any partition; 1 = partition 1;
Any partition 0 2 = partition 2; 3 = partition 3
Press [
∗