EasyManua.ls Logo

Honeywell ADEMCO VISTA SERIES - Page 13

Honeywell ADEMCO VISTA SERIES
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
93
Reports In Armed Period Per
Zone
(Swinger Suppression)
Restrict Report Pairs:
0 = Unlimited Reports
1 = 1 report pair per zone per armed
period
2 = 2 report pairs per zone per armed
period
V20PSIA/V15PSIA:
Restrict Report Pairs:
1 = 1 report pair; 2 = 2 report pairs
Unlimited Reports Enable:
0 = restrict reports to the setting in
entry 1
1 = unlimited reports for zones listed
in zone list 7; (use zone list 7 to
enter those zones that require
unlimited reporting; these zones
ignore the setting in entry 1)
[1,0]
Restrict V20PSIA/V15PSIA
Report Pairs Unlimited Reports Enable
Selection limits the number of alarm/alarm restore message pairs per
zone sent to the CS in an armed period. Swinger suppression applies
to burglary zones only.
SIA Guidelines: Must be set for option 1 or 2
DOWNLOAD INFORMATION (
94,
95)
94
Download Phone No.
Enter up to 20 digits, 0–9; #+11 for '
';
#+12 for '#'; #+13 for a 2-second pause.
Do not fill unused spaces. If fewer than
20 digits, exit field by pressing
. To
clear entries from field, press
94
.
| | | | | | | | | | | | | | | | | | |
Enter the phone number of the downloading computer.
UL: downloading may be performed only if a technician is at the site.
Up/downloading via the Internet has not been evaluated by UL.
95
Ring Count For Downloading
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10,
# +11 =11, # +12 =12, # +13 =13,
# +14 =14);
15 = answering machine defeat
(# +15 =15).
NOTE: Do not enter 0 if using 4286
Phone Module.
[15]
Refer to the chart below and program accordingly.
phone answer down-
module machine loading Set field
95 to
yes no no 1-14 (not 0)
yes yes no greater than rings set on answer machine
(e.g., if ans. machine is 4 rings, set this
field to 5). This allows access to the
phone module if the answer machine is
off.
yes no yes 1-14 (not 0)
yes yes yes 15 (bypasses answer machine
)
no no no 0
no yes no 0
no no yes 1-14
no yes yes 15
NOTE: If “15” is entered to bypass an answering machine, and a 4286
Phone Module is included in the system, you should note the following:
When calling in from an off-premises phone, the user should make the initial
call, allow 1 or 2 rings only, then hang up, then call again. The phone module
will now seize the line, and 2 long tones sound, followed by the usual voice
prompt for the access code. If this procedure is not followed, phone module
operation will not be possible.
96,
97 Initialize/Reset Defaults (
These are commands, not data fields. See page 3.)
98,
99 Exit Commands (
These are commands, not data fields. See page 3.)
PAGER OPTIONS (160- 172)
The system can send various reports to several pagers (VISTA-20P = up to 4; VISTA-15P = up to 2).
To program pager reporting, do the following:
1. Enter the pager phone number(s), preface characters, and pager report options in data fields *160 - *171.
2. Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers).
3. Make sure appropriate user open/close pager reports are enabled (see Security Codes section in User Guide). Users that
perform actions in partition 1 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 1.
Users that perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close reporting in
partition 2.
4. If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then
select event type
03
). System must be armed for the Latchkey report to be sent.
5. If using a function key to manually send a message to a pager, use *57 Function Key Menu mode to define the key
(function
01
).
6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each
pager (zone lists 9-12
).
VISTA-15P supports zone lists 9 and 10 only.
13

Table of Contents