CONVERSION WIRING DIAGRAMS
FOR BC7000L1000
The diagrams and instructions contained in this booklet are for converting the following model
programmers to BC7000 Microcomputer Based Burner Control System.
TABLE OF CONTENTS
Page
Section l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2
Fireye C, D, and E-Series
Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6
Fireye P-Series
Section III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Honeywell R4126, R4127, R4181
Section lV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Honeywell R4140, R4150 with 20 Terminal Subbase (120 V only)
Section V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...29
Honeywell R4150 with 13 or 15 Terminal Subbase
1. Installer must be a trained, experienced, flame safeguard control service technician.
2. Disconnect power supply before beginning installation to prevent electrical shock and
equipment damage.
3. All wiring must comply with applicable local electrical codes, ordinances, and regulations.
4. Voltage and frequency of the power supply and flame detector(s) connected to this control
must agree with those marked on the device.
5. Loads connected to the control terminals must not exceed those listed in the SPECIFI-
CATIONS section.
6. All external timers must be listed or component recognized by authorities having
jurisdiction, for the specific purpose for which they are used.
7. Perform all required checkout tests after installation is complete.
IMPORTANT
For on-off, gas-fired systems, some authorities having jurisdiction prohibit the wiring of any
limit or operating contacts in series with the main fuel valve(s).
P.G.
Rev. 6/89
Form Number 66-6002—4
©Honeywell Inc. 1989
Question and Answer IconNeed help?

Do you have a question about the Honeywell BC7000L1000 and is the answer not in the manual?

Honeywell BC7000L1000 Specifications

General IconGeneral
BrandHoneywell
ModelBC7000L1000
CategoryController
LanguageEnglish

Summary

Section I: Fireye C, D, E-Series Control Conversion

Fireye 70D10/26CF6 Wiring Diagram

Wiring diagram for converting Fireye 70D10, 26CF6, CU6-5065, EP160/161/170 to BC7000L.

Fireye 24CJ5 Wiring Diagram

Wiring diagram for converting Fireye 24CJ5, 25CU6, 70D30, EP380/381/390 to BC7000L.

Fireye 24CJ5 5015 Wiring Diagram

Wiring diagram for converting Fireye 24CJ5 5015, 70D20/26CF6, CU65055, EP260/261/270 to BC7000L.

Section II: Fireye P-Series Control Conversion

Fireye 26RJ8 Wiring Diagram

Wiring diagram for converting Fireye 26RJ8 1016/1012/6012 to BC7000L.

Fireye 25RLJ84580 Wiring Diagram

Wiring diagram for converting Fireye 25RLJ84580 to BC700L.

Fireye 25RU8 Wiring Diagram

Wiring diagram for converting Fireye 25RU8 6560/6570/6580 and 26RJ8 6060/6070/6080/6160 to BC7000L.

Fireye 29RF5 Wiring Diagram

Wiring diagram for converting Fireye 29RF5 1001/1009/6009 to BC7000L.

Fireye 26RJ8 6058 Wiring Diagram

Wiring diagram for converting Fireye 26RJ8 6058/6066/6068 and 25RU8 6558/6566 to BC7000L.

Fireye 26RJ8 1002 Wiring Diagram

Wiring diagram for converting Fireye 26RJ8 1002/1003/1008/1011/1018/6008/6018 and 29RF5 models to BC7000L.

Section III: Honeywell R4126, R4127, R4181 Control Conversion

Honeywell R4126A1172 Wiring Diagram

Wiring diagram for converting Honeywell R4126A1172/1180/1198 to BC7000L.

Honeywell R4126A1008 Wiring Diagram

Wiring diagram for Honeywell R4126A1008-1149 and R4126B1006-1022 series to BC7000L.

Honeywell R4126A1073 Wiring Diagram

Wiring diagram for converting Honeywell R4126A1073/1164 to BC7000L.

Honeywell R4127A1155 Wiring Diagram

Wiring diagram for converting Honeywell R4127A1155/1197 to BC7000L.

Honeywell R4127 Wiring Diagram

Wiring diagram for converting various Honeywell R4127 models (except specific ones) to BC7000L.

Honeywell R4127A1171 Wiring Diagram

Wiring diagram for converting Honeywell R4127A1171/B1039/B1047 to BC7000L.

Honeywell R4181A1000 Wiring Diagram

Wiring diagram for converting Honeywell R4181A1000/1026 to BC7000L.

Honeywell R4181A1018 Wiring Diagram

Wiring diagram for converting Honeywell R4181A1018/1034 to BC7000L.

Honeywell R4181A1042 Wiring Diagram

Wiring diagram for converting Honeywell R4181A1042/1059 to BC7000L.

Section IV: Honeywell R4140/R4150 20-Terminal Subbase Conversion

R4140M/R4150M with Start Interlocks Conversion

Steps for replacing R4140M or R4150M with start interlocks with BC7000L/PM720M2002.

R4140M/R4150M with Preignition Interlocks Conversion

Steps for replacing R4140M or R4150M with preignition interlocks with BC7000L/PM720M2002.

R4140G/R4150G with Start Interlocks Conversion

Steps for replacing R4140G or R4150G with start interlocks with BC7000L/PM720G2005/PM720G2013.

R4140G/R4150G with Preignition Interlocks Conversion

Steps for replacing R4140G or R4150G with preignition interlocks with BC7000L/PM720G2005/PM720G2013.

R4140L/R4150L Conversion

Steps for replacing R4140L or R4150L with BC7000L/PM720L1030/PM720L2004.

Section V: R4150 13- or 15-Terminal Subbase Replacement

R4150A, B, C Models Conversion

Wiring conversion for R4150A, B, and C models to BC7000L/PM720M2002.

R4150G1004 Models Conversion

Wiring conversion for R4150G1004, G1020, G1046, G1103, G1111, G1145, G1178 to BC7000L/PM720G2013.

R4150G1012 Models Conversion

Wiring conversion for R4150G1012 and G1079 models to BC7000L/PM720M2002.

R4150M Conversion

Wiring conversion for R4150M models to BC7000L/PM720M2002.