BENDIX/KING KX 165A
Rev 0, Jun/2000 15610M00.RCD Page 5-31
TEST DATA SHEET
3. Quieting:
Input a standard audio signal at -73 dBm. Monitor receiver and remove modula-
tion.
112.5 MHz: _____________ dB (S+N/N NLT 20 dB)
4. Selectivity:
Using the AGC voltage product by a -93 dBm 112.5 MHz RF signal as a reference
monitor and record the frequencies which reproduce the AGC REF voltage at 6 dB
and 60 dB above the reference input.
112.5 MHz: ________ V REF AGC Voltage
Upper 6dB __________
112.516
Lower 6dB __________
112.484
Upper 60dB _________
112.542 Max.
Lower 60dB _________
112.458 Min.