Page 5-32 15610M00.RCD Rev 0, Jun/2000
TEST DATA SHEET
5. VOR Indication
Input a -73 dBm standard VOR signal into the unit.
*A. Course Accuracy: (Internal course deviation Indicator)
Set the internal OBS to the respective heading in the
VOR CDI mode (Ref fig 3-2)
Radial (Degrees)
Bearing Error D-Bar (0.67
°
)* Max.
0° from _________________________
120° _________________________
240° _________________________
270° _________________________
*(within 1 increment from center position)
B. Course Accuracy: (External Indicator Converter if installed)
Set external PTS to the respective heading. Mea-
sure voltage at D-Bar output.
Radial (Degrees)
Bearing Error D-Bar (2
°
) Max.
0° from __________________
90° __________________
180° __________________
270° __________________